Mitsubishi Electric MELSEC iQ-R Series User Manual page 219

C controller/c intelligent function module secs/gem communication software pre-installed model
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Name
Classi
ficatio
n
ProcessChangeStatus
DVVAL
ProcessState_part01
SV
PreviousProcessState_p
SV
art01
AlarmsEnabled
SV
AlarmsSet
SV
AlarmID
DVVAL
MaxSpoolTransmit
ECV
OverWriteSpool
ECV
MaxSpoolCount
ECV
EnableSpooling
ECV
Description
Format
Process state change state
U1
Current process state
U1
State prior to process state
U1
change
Show the list of alarm IDs in
LIST
the current alarm occurrence
state
Show the list of currently
LIST
occurring alarm IDs
Occurred/ Cancelled Alarm
ID
Maximum No. of Spool
U4
Transmission
Operation upon full spool
BOOL
Maximum no. of spool items
U4
Enable Spooling
BOOL
E30
Variable value
Notes
stan
setting
dard
Register reference
It is defined in processing state model
Can be set
settings.
State number related to the processor
with the changed state is reported from
the programmable controller CPU
1: IDLE
2: SETUP
3: READY
4: EXECUTING
5: PAUSE
32: Setup command IDLE → SETUP
33: Setup completed SETUP → READY
34: Start instruction READY →
EXECUTING
35: Process completed EXECUTING →
IDLE
36: Stop instruction, switch to IDLE
37: Abort instruction, switch to IDLE
38: Pause instruction PROCESS →
PAUSE
39: Resume instruction PAUSE →
Previous PROCESS state
Register notification
It is defined in processing state model
Can be set
settings.
State number related to the
corresponding processor can be
configured for notification to a register
1: IDLE
2: SETUP
3: READY
4: EXECUTING
5: PAUSE
Register notification
It is defined in processing state model
Can be set
settings.
State number related to the
corresponding processor can be
configured for notification to a register
1: IDLE
2: SETUP
3: READY
4: EXECUTING
5: PAUSE
Cannot be set
It is managed within SECS/GEM
communication software.
(0 to 4096)
(Refer to Remarks)
It is defined in alarm definition settings.
The occurring state details are defined in
the alarm state register.
It is managed within SECS/GEM
communication software.
Can be set
It is defined in spool settings.
Default value: 1024 (0 to 4294967295, 0
means all is transmitted)
Can be set
It is defined in spool settings.
0: do not spool further
1: overwrite from the oldest
Default value: 0
Can be set
It is defined in spool settings.
Default value: 32767(1 to 4294967295)
Can be set
It is defined in spool settings.
0: disable spool
1: enable spool
Default value: 0