Data acquisition exclusion

Configure to notify the programmable controller CPU that data, such as equipment variables, is being collected from the host
to the equipment and to prohibit data collection by the host from the programmable controller CPU.
Window
[GEMData]  [Details]  [Data Acquisition Exclusion] tab
Displayed items
Item
Scenario
8 GEM COMPLIANT FUNCTIONS
236
8.17 Advanced Settings
Description
Select a scenario.
The following scenarios can be selected.
• S2F23: Trace condition setting
• S6F15: Event report request
• S6F19: Individual report request
• S1F3: Specified device state request
• S1F11: State variable name list request
• S2F13: Equipment constant request
• S2F29: Equipment constant name list request
• S2F47: Variable limit attribute request
Enable
Select this checkbox to enable data collection exclusion control of scenarios.
Processing Notification
Configure the relay for the SECS/GEM communication software to notify the programmable controller
CPU that processing is occurring for each scenario.
Data Lock
Select this checkbox to turn the data lock relay ON from the programmable controller CPU when locking
data collection from the host.
Lock cannot be enabled after receiving the acquisition message from the host.
The lock should be turned ON in advance based on the equipment state.
Select the "ABORT" checkbox to return an abort message.