Advertisement

DVVAL

Configure the conditions to disable the variables of the DVVAL class.
Window
[GEMData]  [Details]  [DVVAL] tab
Displayed items
Item
DVVAL Disable Settings
Always Enabled
Enabled Only During
Event Report
Occurrence
Individually Specify The
Enable/Disable
Registers
Description
Select to have the variables of the DVVAL class always enabled.
Actual data is sent when sending an S6F11/S6F16/S6F20.
Select to have the variables of the DVVAL class enabled only for S6F11 sending.
When reporting in S6F16 and S6F20, send it as a 0 length item.
Select to specify enable/disable for registers individually and dynamically for variables of the DVVAL
class.
The first word of the specified register is used as the enable/disable register for all user-defined
variables that specify the DVVAL class.
The actual data is stored in the first + one word.
The Enable/disable register specifies "1" If the variable is valid, and "0" from the Programmable
Controller CPU if it is disabled.
8 GEM COMPLIANT FUNCTIONS
8.17 Advanced Settings