7.17
Log Output
Logs of device access with the programmable controller CPU registers and logs of SECS communication with the host can be
output.
Log output setting
Configure the details of the logs to be output.
Common Setting
Series
MELSEC-Q series
MELSEC iQ-R series
Configure the common settings of the log output function.
Window
[Log] [Log Output Setting] [Common Setting] tab
Displayed items
Item
Log Storage Period
Log Output
7 BASIC FUNCTIONS
154
7.17 Log Output
SECS/GEM communication software
Non-GEM version
Description
Configure the number of days to store log data.
The log data is compiled into time-sliced files (in increments of hours), and saved for the specified
number of days.
A log outputted according to FTP settings to the FTP server is not deleted using the SECS/GEM
communication software.
Configure the log output destination.
■MELSEC-Q series
• 0: CF
• 1: FTP
■MELSEC iQ-R series
• 0: SD
• 1: FTP
GEM version
GEM advanced version