CHAPTER 2. Ошибка! Стиль не определен.
No
Code
-
MNF--
65
MNF01
66
MNF02
67
MNF03
68
MNF04
69
MNF05
70
MNF06
71
MNF07
72
MNF08
73
MNF09
74
MNF10
75
MNF11
76
MNF12
77
MNF13
78
MNF14
79
MNF15
80
MNF16
2-408
Alarm Name
Minor Error
Minor Fault with Alarm Buffer saving
Card Out
A circuit card mounted in a universal slot has been
removed from service or is not recognized by the system
Alarm Data = Cabinet, Slot(Cx-Syy)
Card In
A circuit card mounted in a universal slot has been
returned to service.
Alarm Data = Cabinet, Slot(Cx-Syy)
IPC Error
Inter processor communication error has occurred.
Alarm Data = Cabinet-Slot(Cx-Syy)
Trunk Fault
Out of service trunk detected via loop detect. Internal
CODEC test.
Alarm Data = Cabinet, Slot, Port(Cx-Syy-Pzz)
Trunk Recovery
Out of service trunk detected via loop detected as out of
service is now operational.
Alarm Data = Cabinet, Slot, Port(Cx-Syy-Pzz)
Trunk
Out of service trunk detected via seizure of trunk.
Disconnect
External seizure test.
Alarm Data = Cabinet, Slot, Port(Cx-Syy-Pzz)
Trunk Connect
Out of service trunk recovered via seizure of trunk
External seizure test.
Alarm Data = Cabinet, Slot, Port(Cx-Syy-Pzz)
SIO TxQ Over
SIO Tx Queue full error has occurred in the MCP2.
Alarm Data = SIO number(SIO: x)
SIO TxQ Under
SIO Tx Queue under error has occurred in the MCP2.
Alarm Data = SIO number(SIO: x)
E1 Out Of Srv
E1 Digital line status has been changed to out of
service.
Alarm Data = Cabinet, Slot(Cx-Syy)
E1 In Service
E1 Digital line has been restored to normal service.
Alarm Data = Cabinet, Slot(Cx-Syy)
SIO Out
IO port has lost DTR
Alarm Data = SIO number(SIO: x)
SIO In
IO port has regained DTR.
Alarm Data = SIO 1 through 6
TODC Error
Time of Day Clock in the MCP2 has erred.
TSW Over Alarm
The TSW has been requested to exceed the capacity of
available time slots. Maximum 192 per cabinet.
Alarm Data = Cabinet, Slot(Cx-Syy)
PSU Alarm
Indicates there are over 56 ports in a cabinet with a
single PSU and more power is required.
Alarm Data = Cabinet, Slot(Cx-Syy)