System Alarm Assignments - Samsung OfficeServ 500 Programming Manual

Hide thumbs Also See for OfficeServ 500:
Table of Contents

Advertisement

CHAPTER 2. Ошибка! Стиль не определен.

[852] SYSTEM ALARM ASSIGNMENTS

This MMC allows the assignment of system alarms to ring and display the alarms on
stations that have the Alarm Key assigned. The System Alarm Key is programmed in
Station Key Assignments(MMC 722). System Alarm key programming is tenant
wide(tenant 1 and 2). Alarms not programmed to report to the System Alarm key will still
be retained in the maintenance alarm buffer for Alarm Reporting(MMC 851). The alarm
buffer will hold up to 100 alarms on a First In-First Out(FIFO) basis. Pressing the System
Alarm key will silence the audible alarm until another alarm is generated by the system.
Alarm conditions that have multiple causes e.g., PRI errors and synchronization loss will
print all associated alarm information if an SIO port is programmed as an ALARM port.
The specific fault alarm data can be displayed via MMC 851 System Alarm Reporting.
Alarm Notification
Alarm Notification Off/On(0/1) determines if the alarm provides a visual and
audible notification to the System Alarm key station(s). Pressing the System
Alarm key and the release key will silence the audible alarm only at the station
that pressed the System Alarm key and the release key. See alarm displays table
for assignments.
Alarm Code Definition:
No
Code
-
MJA--
01
MJA01
02
MJA02
03
MJA03
04
MJA04
05
MJA05
06
MJA06
2-404
Alarm Name
MCP2 Error
System Fault
POR Restart
MCP2 restart process has been executed via power on
restart(POR).
Soft Restart
MCP2 restart process has been executed via button reset.
MEM Reset
The system RAM has been cleared via manual programming
(PCMMC or KMMC) resulting in a system reset.
MCP Reset
The MCP2 has S/W exception error.
Alarm data = Reason
- BUS ERR: Restart Bus Error
- ADDR.ERR: Restart Address Error
- ILLEGAL: Restart Illegal opcode
- ZERO DIVID: Restart Zero divide
- PRIVILEGE: Restart Privilege Violation
- ENDL LOOP: Restart Endless Loop
LCP Reset
The SCP2 or LCP2 has reset
Alarm data = Cabinet(1, 2 or 3)
PCM Switching
A fault has occurred in the Switching Control
Alarm data = MCP BASE, ESM: 1, ESM: 2 or ESM: 3
Definition