CHAPTER 2. Ошибка! Стиль не определен.

[503] TRUNK-WIDE TIMER

Allows certain trunk timer values to be changed on a per-trunk basis or for all trunks.
It is not advisable to change these values, with the exception of trunk Flash Time, without
assistance from Technical Support.
No
Item
00
ANS.BAK TM
01
CLEARING
02
CO SUPV TM
03
DTMF DUR.
04
F-DGT DELY
05
FLASH TIME
06
NO RING TM
07
PAUSE TIME
08
PRS DET TM
09
RNG DET TM
10
WINK TIME
11
MF/DP INT
12
MFR DLY TM
2-170
Description
ANSWER BACK TIME. This timer is used for certain
types of E & M signaling and does not affect normal
CO lines.
This timer ensures that a call is fully disconnected at
the CO by preventing CO access outgoing or
receiving incoming ring between a disconnect and
the expiration of this timer.
CO SUPERVISION TIME. this is the minimum
length of loop open disconnect received from the
CO that will be seen as a valid hang up on the
system.
DTMF DURATION. This is the length of the DTMF
digits that will be sent to the CO on this line.
First-DIGIT DELAY. This is the length of time the
system will wait for CO line conditions to stabilize
after seizure before sending DTMF digits.
This is the duration of the momentary open sent on
a circuit when FLASH key is pressed.
This is the length of time the system will wait after
detecting a ring burst on a line before deciding the
call has disconnected.
This is the length of time the system will wait before
sending the next digit for a pause in a speed dial
bin.
This means the duration of PRS signal pulse. If the
PRS signal is reversed when opposite party is
answered and maintain the status before the
opposite party disconnect the call, the PRS DET TM
must be set to 0.
RING DETECT TIME. This is the minimum length of
ring signal the system will regard as a valid ring.
This is the duration of the acknowledgment signal
that the system will send on an E & M circuit
This is the interval between sending digit. In case of
DTMF signal, over the 500ms will be serviced as
100 ms.
This is a delay time to allocate the MFR after
incoming trunk is detected. This is to prevent the
wrong detection of DTMF signal by noise.
Range
0-2500 MSEC
100-9900 MSEC
10-2500 MSEC
100-9900 MSEC
100-9900 MSEC
20-2500 MSEC
1-25 SEC
1-25 SEC
0-2500 MSEC
10-2500 MSEC
100-300 MSEC
100-9900 MSEC
0-25 SEC