[703] TOLL ALLOWANCE TABLE

Provides a way to make toll restriction very easy and flexible. There are 250 allowable
entries in the allow table for a OfficeServ 500-M system and 500 allowable entries for a
OfficeServ 500-L system and each entry index can be assigned to a class of service. Each
index can have up to 12 digits. With the use of wild cards(MMC 704 Assign Wild
Character), more flexibility can be built into toll restriction. There are six toll levels, B to G,
that are programmable. Toll level A is set as unrestricted by default, and toll level H is set
as in-house only by default.
CONDITIONS
NONE
DEFAULT DATA
ALL ENTRIES ARE SET TO 0
PROGRAM BUTTONS
A
Used to wild card X entered
B
Used to wild card Y entered
C
Used to wild card Z entered
ACTION
1) Press Transfer button and enter 702.
Display shows:
2) Dial index number.(e.g., 005)
OR
Press Volume button to select index and
press Right Soft button to move cursor.
3) Enter toll pattern via dial pad.(e.g., 202)
OR
Enter wild card(e.g., 21X) from above list and
press Right Soft button to move cursor to COS
Options.
© SAMSUNG Electronics Co., Ltd.
OfficeServ 500 Programming Guide
DISPLAY
ALOW(001):BCDEFG
:000000
ALOW(005):BCDEFG
:000000
ALOW(005):BCDEFG
202
:000000
ALOW(005):BCDEFG
20X
:000000