MUTOH Valuevet VJ-628X Maintenance Manual page 31

Full color ink jet printer
Hide thumbs Also See for Valuevet VJ-628X:
Table of Contents

Advertisement

2.2 Troubleshooting with Error Messages
No.
Message
Event/symptom
20
E141Err
An anomaly is detected
Platen heat Th.
in Platen Thermistor.
21
E 154 Err
Interception of the
AC Volt. Low
power-supply to a
printer or the supply
voltage decreased.
22
E227 Err
This indicates that
Heater SSR
"Heater Off " is not
worked.
2.2.3 Errors Requiring Reboot
Table 2-4 Symptoms and Check Items for Mechanical Serious Errors(Continued)
Check item
1.
Platen Thermistor connector may be
malfunctioning.
2.
Platen Thermistor may be disconnecting.
3.
HEATER DRIVE board may be
malfunctioning.
1.
AC cable may have unplugged.
2.
Instantaneous power failure may have
occurred.
3.
Power board may be damaged.
1.
HEATER DRIVE board may be
malfunctioning.
Action
1.
Make sure to connect thermistor connector
securely.
2.
Replace Thermistor relay.
3.
Replace DRIVE board.
Plug AC cable securely.
Reboot the printer.
Replace Power board.
Replace HEATER DRIVE Board.
VJ628XE-M-00
Reference
"3.11.6Replacing HEATER
DRIVE Board
Operation Manual
Operation Manual
"3.5.1Replacing Power Board
"3.11.6Replacing HEATER
DRIVE Board
31

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Valuevet VJ-628X and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents