Code
CO Termination
09
370
+ 620
10
220
+ 820
11
300
+ 1000
12
270
+ 750
13
200
+ 560
To configure the same CO Termination for all trunks (provided the service provider is the same for all
trunks), dial,
3112-*-
CO Termination Code
To configure the CO Line Type for the trunk, dial,
3113-1-Trunk-
Where,
Trunk is the software port from 0 to 2 for which the test has been conducted.
Code is the value obtained corresponding to Result Index 0.
CO Line Type
Code
CO Line Type
00
EIA-0
01
EIA-1
02
EIA-2
03
EIA-3
04
EIA-4
05
EIA-5
06
EIA-6
07
EIA-7
08
2000 ft. 22 awg
09
2000 ft. 24 awg
10
2000 ft. 26 awg
To configure the same CO Line Type for all trunks (provided the service provider is the same for all
trunks), dial,
3113-*-
CO Line Type Code
Exit SE mode.
Verifying the Test Results
Verify the test results by making a trial call from a station by grabbing the CO trunk on which the test has
been conducted. There should be no echo and speech should be audible and clear.
If you still hear echo during the trial call, you may proceed as follows,
View the codes corresponding to Result Index 1 and apply them to the selected trunk port. If the
performance is still not satisfactory, then view the codes corresponding to Result Index 2 and apply
Matrix VISIONPRO System Manual
+ 310 nF
+ 120 nF
+ 220 nF
+ 150 nF
+ 100 nF
CO Line Type Code