Matrix Visionpro System Manual page 47

Hide thumbs Also See for Visionpro:
Table of Contents

Advertisement

Flash Timer
Flash Timer value
Index
8
101-800
9
101-900
By default, Flash timer index is 6.
If the Flash Timer range is configured as 70-100ms, Pulse dialing for that particular SLT phone will not
work.
To configure the same Flash Timer value for all stations, dial,
4102-*-Flash Timer Index
To configure the Digit Padding for a station, dial,
4104-1-Station-Count
Where,
Station is the software port number of the station from 00 to 07.
Count is from 0 to 9.
By default, the count is 9 for each station.
To configure the same digit padding count for all stations at once, dial,
4104-*-Count
If count is programmed as 0, the calling party's number will be displayed the same which is received. If the
count is programmed between 1 to 9, the digit length of the calling party's number displayed will be equal
to the count. For example, if the count value is programmed as 4 and station number 21 is calling, then two
zeroes will be padded to 21 to maintain the length 4. The display will be '2100'.
To configure the AC Impedance for a station, dial,
4105-1-Station-Code
Where,
Station is the software port number of the station from 00 to 07.
Code
Meaning
0
600
1
900
2
350 + (1000 || 0.21F)
3
220 + (820 || 120nF)
Default AC impedance is 600
To configure the same AC Impedance for all stations at once, dial,
4105-*-Code
To configure the Transmit Gain for a station, dial,
4106-1-Station-Code
Where,
Station is the software port number of the station from 00 to 07.
Code
Gain (in dB)
00
-3
01
0 (Default)
02
3
41
in ms
Matrix VISIONPRO System Manual