Matrix Visionpro System Manual page 119

Hide thumbs Also See for Visionpro:
Table of Contents

Advertisement

Feature Interactions
Call Transfer: In case of transferred call, the CDC timer gets reset and starts again afresh on the
transferred station.
Conference: CDC is treated as turned OFF.
Call Park: CDC is treated as turned OFF.
How to configure
Call Duration Control can be enabled/disabled for each station for the following cases,
Call Duration Control for Outgoing (External) calls.
Call Duration Control for Incoming (External) calls.
Call Duration Control for Internal calls.
Configuring CDC parameters (such as enabling CDC for different types of calls, defining the CDC timer, assigning
Allowed and Denied lists) forms a table which is called the CDC Table. Decide the CDC table that you should
configure. Each CDC table would appear as shown below:
Parameter
Internal Call Control
Incoming Call Control
Outgoing Call Control
Allowed List
Denied List
CDC Timer
CDC Disconnection Flag
Maximum four CDC tables can be programmed.
One such table can be assigned to the station user.
All CDC tables are available by default and they satisfy most of the requirements. Hence these tables
can be directly assigned to the stations.
The default CDC Table is configured as follows,
CDC Table Meaning
0
CDC OFF for all calls
1
CDC ON for Outgoing STD and ISD calls
2
CDC ON for Outgoing 95, 98, STD and ISD calls
3
CDC ON for all Outgoing calls
113
Value
Yes/No
Yes/No
Yes/No
List Number from 0 to 7
List Number from 0 to 7
000-999 seconds
Yes/No