System Security (SE and SA Passwords)

VISIONPRO's programming mode is secured at three levels,
System Engineer level. This level is protected by the SE Password.
System Administrator level. This level is protected by the SA Password.
User level. This level is protected by the User Password.
System Engineer (SE) Password
This password is the main password of the system and should be kept secret for exclusive use only by the
System Engineer. SE Password is needed to enter the System Engineer mode of the system to change
any setting of the system.
SE Password is a 4-digit password. Valid digits are 0-9
The System Engineer may not know the SA Password or the User Password. However, SE can clear
these passwords and set them to their default values.
How to configure
To change the SE Password,
Enter SE mode.
Dial, 1104-Old SE Password-New SE Password
Where,
New SE Password is a number string of 4-digits.
Default SE Password is 1234.
Exit SE mode.
System Administrator (SA) Password
The System Administrator uses this password.
SA Password is a 4-digit password. Valid digits are 0-9
How to configure
To change the SA Password,
Enter SE mode.
Dial, 1105-Old SA Password-New SA Password
Where,
New SA Password is a number string of 4-digits.