Summary of Contents for Matrix ETERNITY ME

  • Page 1 ETERNITY Quick Start...
  • Page 3 ETERNITY The IP-PBX with Seamless Mobility and Universal Connectivity Quick Start...
  • Page 4 Documentation Disclaimer Matrix Comsec reserves the right to make changes in the design or components of the product as engineering and manufacturing may warrant. Specifications are subject to change without notice. This is a general documentation for all models of the product. The product may not support all the features and facilities described in the documentation.
  • Page 5: Table Of Contents

    Contents Introduction ....................1 Installing the ETERNITY ................3 Before you Start ....................3 Installing SLT, DKP and TWT Cards ..............6 Installing the BRI Card ..................7 Installing E&M Card ..................13 Installing Mobile Card ..................15 Installing VoIP Card ..................18 Connecting SIP Extensions ................
  • Page 6: Table Of Contents

    VoIP Port ......................69 SIP Trunks ....................... 70 SIP Extensions ....................70 Logical Partition ....................72 Door Phone Card .................... 73 VMS Card ......................73 Appendix ....................... 85 Universal Slots ....................85 Cable Diagrams for cards of ETERNITY-ME ..........88 Cable Diagram for cards of ETERNITY-GE ..........
  • Page 7: Introduction

    Introduction Thank you for choosing the Matrix ETERNITY! This Quick Start is meant to help you setup the ETERNITY and use the basic features. For detailed description of the installation, advanced configuration and feature description, please refer the ETERNITY System Manual provided to you on the CD- ROM.
  • Page 8 Matrix ETERNITY Quick Start...
  • Page 9: Installing The Eternity

    Installing the ETERNITY Before you Start Before you begin the installation of the ETERNITY ME/GE/PE, make sure that the required telecom wiring has been done and you have the following items ready: • A Main Distribution Frame (MDF) • A suitable location to install the Main Distribution Frame and the ETERNITY hardware.
  • Page 10 User Card CD containing Voice Messages, System Manual, Quick Start and User Card. Wall mounting nails Matrix Logos Mounting Template Support Card Telephone Personality Guide Warranty Card MDF cable for Switch Card (provided with ETERNITY ME only) Matrix ETERNITY Quick Start...
  • Page 11 • Place the system at the location you have selected. • If installing ETERNITY ME or GE, • unscrew and remove the filler bracket of the slots you want to insert the cards. • insert the cards into the Universal Slots. Make sure the connectors on the card and those on the motherboard on the backplane make perfect contact.
  • Page 12: Installing Slt, Dkp And Twt Cards

    MDF. • Connect Digital Key phones, EON42, EON48 and their consoles DSS72 and DSS16X4 to the DKP Ports over the MDF. • Connect Two Wire Trunk (Analog Trunk) lines to the TWT ports over the MDF. Matrix ETERNITY Quick Start...
  • Page 13: Installing The Bri Card

    Set the Orientation Type of the BRI Ports as Terminal (TE) or Network (NT) mode as per your installation requirement. In ETERNITY ME • To set the Orientation Type of the BRI Port as either NT or TE, change the position of the jumpers located on the main board of the card.
  • Page 14 Jumpers on the main board of the BRI Card. Default: all ports are set as TE. Mode Jumper Position BRI Port 1 BRI Port 2 Mode Jumper Position BRI Port 3 BRI Port 4 Matrix ETERNITY Quick Start...
  • Page 15 Mode Jumper Position BRI Port 1 BRI Port 2 Common Instructions for installing the BRI card in ETERNITY ME, GE, and PE • A BRI Port can be configured in the TE/NT mode. Depending on the installation and configuration scenario, Termination Resistance of 100 should be inserted.
  • Page 16 (daughter board) of the BRI Card as shown in the table. Function Jumper Position To feed power on Tx and Rx wires (Phantom Power) To feed power on separate pair of wires No power to be fed to the terminal equipment (default position) Open Open Matrix ETERNITY Quick Start...
  • Page 17 Pin Number Pin Details Configuration of the S/T interface (RJ-45) on NT1 Pin Number Pin Details Pin details of BRI Port in TE mode Pin Number Signal Color Orange-White Orange TX-A Green-White RX_A Blue RX_B Blue-White Matrix ETERNITY Quick Start...
  • Page 18 Blue-White RX_B Green VOUT- Brown-White VOUT+ Brown This is a typical connection of a BRI Line to the ETERNITY ME BRI port in the TE mode: LED indication for BRI Ports Port Status LED Color LED Cadence Port active Continuously ON...
  • Page 19: Installing E&M Card

    Tie Line equipment with appropriate crossing of the wires. • For connecting the wires, refer the pinout details for each E&M Card Type and for each E&M Type and Speech Interface Type given in the “Appendix”. Matrix ETERNITY Quick Start...
  • Page 20 All LEDs Toggle at 1 sec failure External RAM failure Orange All LEDs Toggle at 2 sec Eprom failure Orange All LEDs Toggle at 3 sec Invalid Slot detected Orange All LEDs Toggle at 6 sec Matrix ETERNITY Quick Start...
  • Page 21: Installing Mobile Card

    Failure to follow the instructions on PIN protection may cause your SIM Card to be blocked and you will require Personal Unblocking Number (PUK) to reactivate it again. • To insert the SIM cards into the SIM holders, refer the illustrations of the Mobile cards. Matrix ETERNITY Quick Start...
  • Page 22 ETERNITY ME GSM/3G 8 Card Insert SIM Card Contact facing down Antenna 1 Antenna 2 ETERNITY GE GSM/3G 4 Card Insert SIM Card Contact Facing down Antenna Matrix ETERNITY Quick Start...
  • Page 23 200ms On-200ms Off- 200ms On- 2400ms Off (2 Blinks) Network Link Down Orange 200 ms On-2800 ms Off (1 Blink) (absence of Network) There is no LED on the Mobile Cards of ETERNITY GE and ETERNITY PE. Matrix ETERNITY Quick Start...
  • Page 24: Installing Voip Card

    IP Network or in a Private network (behind a NAT Router). It can also be connected to both networks. VoIP Card installed in Public Network VoIP Card installed in a Private Network ETERNITY ME16S Master Ethernet Port LAN Switch/Hub Router Matrix ETERNITY Quick Start...
  • Page 25 VoIP Card connected to the Public and Private Network for Matrix Extended IP phones • Unpack VoIP Card. • Insert VoIP Card in any free universal slot and secure it in its slot, and secure the card in its slot.
  • Page 26 • The ETERNITY ME and GE VoIP Cards have two LEDs: • LED 1 indicates the status of the VoIP card. • LED 2 indicates the status of any of the SIP Trunks to which this LED is assigned. •...
  • Page 27 On 500msec-Off 2500 msec Registration in Progress Green On 500msec-Off 3500 msec Registration Successful Green Continuous On SIP Trunk Status will be indicated by LED2 only after you have programmed the Registration LED in the SIP Trunk Parameters. Matrix ETERNITY Quick Start...
  • Page 28: Connecting Sip Extensions

    Management’ in the System Manual. You may connect the Standard and Extended IP Phones of Matrix. The Matrix Extended IP Phone, SETU VP248, takes on all the functions of EON48, the proprietary digital key phone of Matrix, except the following features: •...
  • Page 29 The Master Ethernet Port is used for Auto Configuration of the Matrix Extended IP Phones. When you register a SIP device other than the Matrix Extended IP Phone on the public network as SIP Extension of ETERNITY, in this SIP device, you must configure the following: •...
  • Page 30 The Master Ethernet Port is used for Auto Configuration of the Extended IP Phones. Connecting SETU VP248 as Extended SIP Extension You are recommended to complete the following steps before connecting the Matrix Extended IP Phone to ETERNITY: • Decide the location of the Extended IP Phone, whether within the same network or outside, according to your installation scenario.
  • Page 31 • Assign the Registrar Server IP Address, as per you installation scenario. For instructions, see the topic Matrix Extended IP Phone Settings under Configuring SIP Extensions in the System Manual. Now, follow the steps described below to install the Extended IP Phone. The instructions are common for all models of the SETU VP248.
  • Page 32 Now, mount the phone on the wall, with the screws fitting into the Keyhole slots. • When you mount the phone on a desk, you can attach the Foot Stand in two ways as illustrated in the following. Foot Stand attached at 20 Angle Matrix ETERNITY Quick Start...
  • Page 33 Plug the long straightened end of the phone cord into the handset jack at the bottom of the phone marked with the handset symbol. • Plug the other (short straight) end of the phone cord into the jack at the bottom of the handset. Matrix ETERNITY Quick Start...
  • Page 34 If your phone supports Power over Ethernet (PoE), and you want to use PoE, make sure that your LAN supports PoE. Supply power through an 802.3af connection on the LAN Port of the phone. Do not connect the Adapter! Matrix ETERNITY Quick Start...
  • Page 35 S e l e c t t h e f i r m w a r e S t a n d a r d S I P E x t e n d e d S I P Matrix ETERNITY Quick Start...
  • Page 36 If you want to change the Network Settings, press the Enter key. Detailed instructions for changing the Network Settings of the phone are provided at the end of this topic. See “Network Settings”at the end of this topic. Matrix ETERNITY Quick Start...
  • Page 37 D H C P d i s c o v e r y. . . ! • On getting the IP Address and Server Address, the phone initiates Auto Configuration to download the configuration files from ETERNITY ME. • As the phone downloads the configuration files, the file names will appear one by one.
  • Page 38 To make a selection in the menu, you must move the cursor in the desired direction using the Up, Down, Forward and Back key. When the cursor is at the desired position, press Enter key to make a selection. Matrix ETERNITY Quick Start...
  • Page 39 Mute Conference Transfer Mute Conference Transfer Forw ard Forw ard DN D DN D Names Names Redial Redial Release Release Hold Hold Local Menu pqrs pqrs wxyz wxyz CA04 CA04 CA03 CA03 CA02 CA02 CA01 CA01 Matrix ETERNITY Quick Start...
  • Page 40 Select the Connection Type as DHCP, PPPoE or Static according to the IP Addressing scheme of your network. If you select DHCP or PPPoE, the phone will be assigned IP Address, Subnet Mask and Gateway Address, DNS Address Server Address, automatically by the DHCP/PPPoE server. Matrix ETERNITY Quick Start...
  • Page 41 However, if your Internet Service Provider does not provide DNS Address, select Static and configure the DNS Address. DNS Address • If you select DNS Server as Static, enter the DNS Address here. To enter dot/period in the IP Address, press the digit key ‘1’ twice. Matrix ETERNITY Quick Start...
  • Page 42 • Enter the Web Server Port of the Master Ethernet Port of ETERNITY here. The phone sends the request for configuration files to this port. Valid range of the port is: 80 or 1024–65535. Default: 80. Matrix ETERNITY Quick Start...
  • Page 43 Quality of Service (QoS), i.e. better handling of data that pass over a network, thereby resulting in greater reliability and quality. Quality of Service (QoS) on Layer2 is referred to as Class of Service (CoS) which is defined by IEEE 802.1P. Matrix ETERNITY Quick Start...
  • Page 44 2 MB of packets. For more information and for instructions on how to use PCAP Trace on the phone, see the topic ‘Using PCAP Trace for the Matrix Extended IP Phone’, under PCAP Trace in the System Manual.
  • Page 45 Ethernet Port of ETERNITY. • S. PORT: The Web Server Port of the Master Ethernet Port of ETERNITY. • DOMAIN: The Domain Name assigned to the phone. • FIRM: The version of the current Firmware of the phone. Matrix ETERNITY Quick Start...
  • Page 46: Installing The T1E1Pri Card

    By default, termination resistance of T1E1 port set as 120 for E1 connectivity. • To use the T1E1 port for T1 connectivity, termination resistance should be changed to 100. In ETERNITY ME • T1E1Port -1 termination resistance can be changed using DIP switch SW5. •...
  • Page 47 • Connect one end of the RJ45 cable provided with the T1E1PRI Card of ETERNITY ME/GE/PE to the T1E1 Port and the other end to the modem provided by the ISDN Service Provider. LED indication of T1E1PRI Card of ETERNITY-ME and ETERNITY-GE are shown below.
  • Page 48 MFA Alarm 100ms ON-100 ms OFF BFA Alarm 500ms ON-500 ms OFF LOS Alarm Continuous ON LED2/LED4 Pattern: Port Status Color Cadence Layer 1 established successfully GREEN Continuous ON Y-Bit Alarm GREEN 100ms ON-100 ms OFF Matrix ETERNITY Quick Start...
  • Page 49 Near end loop back wait before activate 100ms ON-100 ms OFF Near end loop active Continuous ON Near end loop back wait before deactivate 500ms ON-500 ms OFF Far end loop back wait after activate GREEN 100ms ON-100 ms OFF Matrix ETERNITY Quick Start...
  • Page 50 GREEN Continuous ON Far end loop back wait after deactivate GREEN 500ms ON-500 ms OFF Port Disable Mode LED1/LED3 Pattern: Port Status Color Cadence Port Disable Continuous ON LED2/LED4 Pattern: Port Status Color Cadence Port Disable Matrix ETERNITY Quick Start...
  • Page 51: Installing Vms Card

    If you need to generate configuration and debug reports, connect the COM Port of the VMS Card with that of a PC using the communication cable supplied with the card. There is no LED on the VMS Card of ETERNITY PE. Matrix ETERNITY Quick Start...
  • Page 52 The IP Address of the Ethernet Port of the VMS Card and the Ethernet Port of the LAN PC are not the same. • The Ethernet Port of the VMS Card and the Ethernet Port of the PC are in the same Subnet. Matrix ETERNITY Quick Start...
  • Page 53: Installing Door Phone Card

    If using a Door Phone, you can connect a door lock release device to the Digital Output Port to be used in conjunction with the Door Phone.  Do not connect any device that does not conform with the Technical Specifications of the ports! Matrix ETERNITY Quick Start...
  • Page 54 A typical Installation of the Door Phone Card is illustrated below. Matrix ETERNITY Quick Start...
  • Page 55: Switching On The System

    Switching ON the system • Switch ON the system, it takes 2 to 3 minutes for initiation. Reset Cycle on ETERNITY ME and GE • On completion of the initialization, LED L1 on Master Card/CPU Card will blink Green with cadence of 1Sec ON - 1 Sec OFF, continuously.
  • Page 56: How To Access Jeeves

    How to access Jeeves ETERNITY provides a Graphic User Interface (GUI), Jeeves, the proprietary web- based programming software of Matrix. It is an HTTP server built into the ETERNITY. Jeeves can be accessed by connecting the Master Ethernet Port of ETERNITY with the Ethernet Port of a standalone computer or a LAN Switch/Hub.
  • Page 57 For example, issue command 2110-192168050010, to change the IP Address as (192.168.50.10). To change the Subnet Mask, dial the command 2111-<Subnet Mask> Dial 00 to exit from SE Mode. Matrix ETERNITY Quick Start...
  • Page 58 Matrix ETERNITY Quick Start...
  • Page 59: Basic Configuration

    Enter the current IP address of Master Ethernet Port of ETERNITY on the address bar of the browser. This may be the default IP Address or the IP Address you reassigned to ETERNITY’s Master Ethernet Port (refer “How to access Jeeves”). • Click Login as System Engineer. Matrix ETERNITY Quick Start...
  • Page 60 The Login page of the System Engineer mode on Jeeves will open. • Now, enter the valid SE password. The default SE password is 1234. • On successful login, the following programming options appear on your screen. Matrix ETERNITY Quick Start...
  • Page 61: Region

    ETERNITY in a country other than India, change ‘Region’. To do this, • Click the Regional Settings link. • Click the Region Selection link to open the page. • In the Region list, select the country the system is installed. Matrix ETERNITY Quick Start...
  • Page 62: Emergency Numbers

    Enter the name of the Enterprise/Organization using ETERNITY. The name may be up to a maximum of 80 characters. You may also add the contact address line, if desired. • Click Submit to save changes to this page. Matrix ETERNITY Quick Start...
  • Page 63: Time Zone-Automatic (Time Table), Day/Night Mode

    SIP Extension: 3301 to 3800 You can change the flexible numbers of these station types according to your preference, on their respective configuration pages: • Go to ‘SLT Parameters’ page under ‘SLT Configuration’ to change the flexible numbers of SLTs. Matrix ETERNITY Quick Start...
  • Page 64: Dss Consoles

    Digital Key Phones are connected on the 1st and 2nd port of the DKP Card. • One DSS is connected to 3rd port of DKP Card. • Second DSS is connected on 4th port of the DKP Card. Matrix ETERNITY Quick Start...
  • Page 65 To assign the first DSS to the first DKP, assign Slot5, Port 03 as one in “DKP DSS 1 H/w Slot - Port” of the software port of DKP 1. Similarly, to the second DSS to the first DKP, assign Slot5 and Port4 as “DKP DSS 2 H/w Slot - Port”. Matrix ETERNITY Quick Start...
  • Page 66: Clip

    Go to ‘Class of Service’ page to check the default settings of the CoS group 01 and customize CoS1 group as required. • To change the CoS group assigned to the station; go to ‘Station Basic Feature Template’. Matrix ETERNITY Quick Start...
  • Page 67: Toll Control

    Station Basic Feature Template - 01. Trunk Access • Trunk Access is part of Station Basic Feature Template; by default all stations are assigned Station Basic Feature Template-01. • By default all stations are assigned Outgoing Trunk Bundle Group (OGTBG)-01. Matrix ETERNITY Quick Start...
  • Page 68: Trunk Landing

    By default DID is disabled on all the trunks for working hours, break hours and non-working hours. • To enable DID, go to ‘Trunk Feature Template’ and enable the DID for working hours, break hours and non-working hours as desired. Matrix ETERNITY Quick Start...
  • Page 69: Cli Based Routing

    By default Direct Inward System Access (DISA) is disabled on all the trunks for working hours, break hours and non-working hours. • To enable DISA for working, non-working and break hours, go to ‘Trunk Feature Template’ of the trunks on which this feature is to be enabled. Matrix ETERNITY Quick Start...
  • Page 70: T1E1Pri

    T1E1 port. • By default, the T1E1 port is set to support “E1 PRI” signaling. Go to ‘Port Parameters’ - ‘Signal Type’ to change the signaling as T1 PRI/E1 CAS/T1 RBS as supported by the exchange (Network). Matrix ETERNITY Quick Start...
  • Page 71 Go to ‘T1 RBS Signaling’, to change the attributes of the T1 RBS signaling. • EachT1E1 Port is assigned following templates in default configuration: • Trunk Feature Template Number 01 • Station Basic Feature Template Number 01 • Station Advance Feature Template Number 01 Matrix ETERNITY Quick Start...
  • Page 72: Mobile Port

    Manual. Program the Network Operator code (MCC-MNC) in priorities for the Mobile Port. • All Mobile Port attributes are to be configured under ‘Mobile Port Parameters’ and ‘Network Selection’. • By default, Mobile ports are assigned Trunk Feature Template number 01. Matrix ETERNITY Quick Start...
  • Page 73: Bri Port

    On Demand • Always ON • Select the 'Layer 1 Mode' parameter, depending upon the type of line, terminated on the BRI Port of ETERNITY. • By default, the Layer-1 Mode for all BRI-TE is 'Always ON'. Matrix ETERNITY Quick Start...
  • Page 74: E&M Lines

    Orientation type, go to ‘E&M Feature Template’. • By default the Dial Type for the E&M port is Pulse, with Pulse Dial Ratio 10PPS 1:2. You can change the Dial Type to Tone Type, as required on the ‘E&M Feature Template’. Matrix ETERNITY Quick Start...
  • Page 75: Voip Port

    Address, Network Mask and Gateway Address. • Program the PPPoE User name, Password and PPPoE Service Name as provided by the Internet Service Provider. Program PPPoE Service Name only if provided by the Service Provider, else keep this field blank. Matrix ETERNITY Quick Start...
  • Page 76: Sip Trunks

    ITSP. SIP Extensions ETERNITY supports upto 999 SIP extensions on its VoIP Card, depending on the model you have. To configure SIP Extensions, • Go to ‘SIP Extension General Parameters’ under ‘VoIP Configuration’. Matrix ETERNITY Quick Start...
  • Page 77 Enable Authentication of any or all of the SIP Message Options: REGISTER Request, INVITE Request, SUBSCRIBE Request, Voice mail (VM), Subscription, Busy Lamp Field (BLF), PUBLISH. By default, the SIP Message Options REGISTER, INVITE, SUBSCRIBE are enabled. Matrix ETERNITY Quick Start...
  • Page 78: Logical Partition

    Now, on the web page 'Logical Partition', select the option ‘allow/restrict’ from the box to manage call traffic between different categories of trunks and with the VoIP Trunk. • For more information, refer the description for , 'Logical Partition' in the System Manual. Matrix ETERNITY Quick Start...
  • Page 79: Door Phone Card

    Default access code of the VMS group is 3931, You may change this access code on the ‘Access Codes’ page of Jeeves. • To land incoming calls on VMS, program Routing Group 96 as Trunk Landing Group (TLG) in the trunk feature template assigned to the respective trunks. Matrix ETERNITY Quick Start...
  • Page 80 Dial VMS Group access code (Default 3931) from any station. • VMS will answer the call and greet with Welcome Message. • Dial *19-1234 (1234 is the default SE Password of VMS) during the Welcome message. • VMS will prompt you: “Enter the Programming Command”. Matrix ETERNITY Quick Start...
  • Page 81 The VMS card will restart once you enter this command. You may also connect the VMS card port to the LAN of the organization. But make sure that the VMS card and the computer you are using to access it are in the same Subnet. Matrix ETERNITY Quick Start...
  • Page 82 The login page will open.  The web interface Jeeves is common for the ETERNITY VMS Card and CadencePro, the standalone Voice mail System of Matrix Comsec. • You can enter the User name of your choice. (Entering the user name is not mandatory for login.)
  • Page 83 To change the Region, click the ‘System Parameters’ link. • Select the Region from the list and Submit the page. • The following parameters will be changed as per the Region you selected: • Operator code for Home Node Matrix ETERNITY Quick Start...
  • Page 84 Program the start time and end time of working hours for weekdays in the Time Table. The remaining time would be considered as Non-working hours. • DID Welcome messages are played according to the time table programmed. Matrix ETERNITY Quick Start...
  • Page 85 By default, no station is assigned a Mailbox. • Assign the Mailbox number (001-512) to the Station Number to which mailbox facility is to be given. Enter ‘ 000’ if you do not want to assign any mailbox number. Matrix ETERNITY Quick Start...
  • Page 86 Start Time for Time Zone 1-Time Zone 4: • By default, Start Time = 00.00. • Start time of Time Zone 2 is the End time of Time Zone 1 and so on. Thus, program the Start time accordingly. Matrix ETERNITY Quick Start...
  • Page 87 Configuring the Mailbox Parameters: • Click the link “Mailbox Parameters” and Mailbox Parameters Web page will open as given below: Matrix ETERNITY Quick Start...
  • Page 88 If you are using TWT trunk and have enabled DID (Auto Attendant) on the same trunk, enable Disconnect Tone Detection and program Disconnect Tone Cadence in ‘TWT Hardware Template’ assigned to this trunk. • For more details refer, ETERNITY System Manual. Matrix ETERNITY Quick Start...
  • Page 89 Change the SE password • When you have finished installation, you are advised to change the SE password to prevent unauthorized access. • Go to ‘Change SE P/w’ to change the SE password. Matrix ETERNITY Quick Start...
  • Page 90 Matrix ETERNITY Quick Start...
  • Page 91: Appendix

    Appendix Universal Slots ETERNITY ME16S ETERNITY ME10S Matrix ETERNITY Quick Start...
  • Page 92 ETERNITY ME10S with Redundancy Option ETERNITY GE12S ETERNITY GE6S ETERNITY GE3S Matrix ETERNITY Quick Start...
  • Page 93 ETERNITY PE6S ETERNITY PE3SP ETERNITY PE3SS Matrix ETERNITY Quick Start...
  • Page 94: Cable Diagrams For Cards Of Eternity-Me

    Cable Diagrams for cards of ETERNITY-ME ETERNITY ME Switch Card Port Color DKP01 (Pin 01-13) Blue-White DKP02 (Pin 02-14) Orange-White DKP03 (Pin 03-15) Green-White DKP04 (Pin 04-16) Brown-White AIP (Pin 05-17) Grey-White AOP (Pin 06-18) Blue-Red Matrix ETERNITY Quick Start...
  • Page 95 ETERNITY ME SLT8 Connector Color Connection H/w Port Offset RJ45-1 Blue - (Blue & White) (Blue) Orange - (Orange & White) Green - (Green & White) Brown - (Brown & White) RJ45-2 Blue - (Blue & White) (Orange) Orange - (Orange & White) Green - (Green &...
  • Page 96 ETERNITY ME SLT16 / ETERNITY ME ILC16 Connector Color Connection H/w Port Offset RJ45-1 Blue - (Blue & White) (Blue) Orange - (Orange & White) Green - (Green & White) Brown - (Brown & White) RJ45-2 Blue - (Blue & White) (Orange) Orange - (Orange &...
  • Page 97 ETERNITY ME SLT32 / ETERNITY ME ILC32 Connector Color Connection H/w Port Offset RJ45-1 Blue - (Blue & White) (Blue) Orange - (Orange & White) Green - (Green & White) Brown - (Brown & White) RJ45-2 Blue - (Blue & White) (Orange) Orange - (Orange &...
  • Page 98 ETERNITY ME DKP8 Connector Color Connection H/w Port Offset RJ45-1 Blue - (Blue & White) (Blue) Orange - (Orange & White) Green - (Green & White) Brown - (Brown & White) RJ45-2 Blue - (Blue & White) (Orange) Orange - (Orange & White) Green - (Green &...
  • Page 99 ETERNITY ME DKP16 Connector Color Connection H/w Port Offset RJ45-1 Blue - (Blue & White) (Blue) Orange - (Orange & White) Green - (Green & White) Brown - (Brown & White) RJ45-2 Blue - (Blue & White) (Orange) Orange - (Orange & White) Green - (Green &...
  • Page 100 ETERNITY ME DKP32 Connector Color Connection H/w Port Offset RJ45-1 Blue - (Blue & White) (Blue) Orange - (Orange & White) Green - (Green & White) Brown - (Brown & White) RJ45-2 Blue - (Blue & White) (Orange) Orange - (Orange & White) Green - (Green &...
  • Page 101 ETERNITY ME TWT8 Connector Color Connection H/w Port Offset RJ45-1 Blue - (Blue & White) (Blue) Orange - (Orange & White) Green - (Green & White) Brown - (Brown & White) RJ45-2 Blue - (Blue & White) (Orange) Orange - (Orange & White) Green - (Green &...
  • Page 102 ETERNITY ME TWT16 Connector Color Connection H/w Port Offset RJ45-1 Blue - (Blue & White) (Blue) Orange - (Orange & White) Green - (Green & White) Brown - (Brown & White) RJ45-2 Blue - (Blue & White) (Orange) Orange - (Orange & White) Green - (Green &...
  • Page 103 ETERNITY ME TWT8 + SLT24 Connector Color Connection H/w Port Offset RJ45-1 Blue - (Blue & White) (Blue) Orange - (Orange & White) Green - (Green & White) Brown - (Brown & White) RJ45-2 Blue - (Blue & White) (Orange) Orange - (Orange &...
  • Page 104 ETERNITY ME SLT8-Magneto8 Card Connector Color Connection H/w Port Offset RJ45-1 Blue - (Blue & White) (Blue) — Orange - (Orange & White) — Green - (Green & White) Magneto Brown - (Brown & White) — — RJ45-2 Blue - (Blue & White) (Orange) Orange - (Orange &...
  • Page 105 ETERNITY ME TWT8-Magneto8 Card Connector Color Connection H/w Port Offset RJ45-1 Blue - (Blue & White) (Blue) — Orange - (Orange & White) — Green - (Green & White) Magneto Brown - (Brown & White) — — RJ45-2 Blue - (Blue & White) (Orange) Orange - (Orange &...
  • Page 106 ETERNITY ME SLT8+MAG2+TWT2+LD2+ENM2 Card Connector Port Type Colour RJ45-1 SLT 01 Blue - (Blue & White) SLT 02 Orange - (Orange & White) SLT 03 Green - (Green & White) SLT 04 Brown - (Brown & White) RJ45-2 SLT 05 Blue - (Blue &...
  • Page 107 ETERNITY ME E&M8 - RJ45 Connector Pin No. Connection Colour H/w Port Offset Open Gray Green-White M OUT Green RX SPCH A Orange-White RJ45-1 SPCH A Blue Pin No. Connection Colour H/w Port Offset SPCH B Blue-White RX SPCH B...
  • Page 108 ETERNITY ME E&M8 - Amphenol Connector E&M08 CARD E&M08 CARD (Lower MDF Connector) (Upper MDF Connector) Port Color Port Color E&M01-M, SB Blue-White E&M05-M, SB Blue-White E&M01-E, SG Orange-White E&M05-E, SG Orange-White E&M01-SP(RxA), SP(RxB) Green-White E&M05-SP(RxA), SP(RxB) Green-White E&M01-SP(A), SP(B) Brown-White E&M05-SP(A), SP(B)
  • Page 109 ETERNITY ME E&M4 - RJ45 Connector Connection Colour H/w Port Offset Open Gray L1 L2 Green-White Connection Colour H/w Port M1 OUT Green RX1 SPCH A Orange-White Offset SPCH1 A Blue Open Gray SPCH1 B Blue-White RJ45-1 Green-White RX1 SPCH B...
  • Page 110 E&M03-SP(RxA), SP(RxB) Orange-Black E&M03-04 CCS Green-Black E&M04-M, SB Brown-Black E&M04-E, SG Grey-Black E&M04-SP(RxA), SP(RxB) Blue-Yellow E&M04-SP(A), SP(B) Orange-Yellow ETERNITY ME BRI4/BRI8 BRI04/BRI08 CARD (Lower MDF Connector) Port Port Port Color BRI01 TxA, TxB Blue-White BRI05 TxA, TxB Blue-White BRI01 RxA, RxB...
  • Page 111: Cable Diagram For Cards Of Eternity-Ge

    ETERNITY ME Magneto8 Port Color Magneto1 (Pin01 Ring - Pin 19 Tip) Blue-White Magneto2 (Pin02 Ring - Pin 20 Tip) Orange-White Magneto3 (Pin03 Ring - Pin 21 Tip) Green-White Magneto4 (Pin04 Ring - Pin 22 Tip) Brown-White Magneto5 (Pin05 Ring - Pin 23 Tip)
  • Page 112 Orange - (Orange & White) Green - (Green & White) Brown - (Brown & White) RJ45-2 Blue - (Blue & White) (Orange) Orange - (Orange & White) Green - (Green & White) Brown - (Brown & White) Matrix ETERNITY Quick Start...
  • Page 113 Orange - (Orange & White) Green - (Green & White) Brown - (Brown & White) RJ45-5 Blue - (Blue & White) (Gray) Orange - (Orange & White) RJ45-6 Blue - (Blue & White) (Red) Orange - (Orange & White) Matrix ETERNITY Quick Start...
  • Page 114 Orange - (Orange & White) Green - (Green & White) Brown - (Brown & White) RJ45-4 Blue - (Blue & White) (Brown) Orange - (Orange & White) Green - (Green & White) Brown - (Brown & White) Matrix ETERNITY Quick Start...
  • Page 115 Orange - (Orange & White) Green - (Green & White) Brown - (Brown & White) RJ45-4 Blue - (Blue & White) (Brown) Orange - (Orange & White) Green - (Green & White) Brown - (Brown & White) Matrix ETERNITY Quick Start...
  • Page 116 BRI Port in TE Mode BRI Port in NT Mode Color Connection Color Connection Orange-White Not connected Orange-White Not connected Orange Not connected Orange Not connected Green-White Green-White Blue Blue Blue-White Blue-White Green Green Brown-White Brown-White Brown Brown Matrix ETERNITY Quick Start...
  • Page 117: Cable Diagram For Cards Of Eternity-Pe

    Orange - (Orange & White) Green - (Green & White) Brown - (Brown & White) RJ45-2 Blue - (Blue & White) (Orange) Orange - (Orange & White) RJ45-3 Blue - (Blue & White) (Green) Orange - (Orange & White) Matrix ETERNITY Quick Start...
  • Page 118 Orange - (Orange & White) Green - (Green & White) Brown - (Brown & White) RJ45-2 Blue - (Blue & White) (Orange) Orange - (Orange & White) RJ45-3 Blue - (Blue & White) (Green) Orange - (Orange & White) Matrix ETERNITY Quick Start...
  • Page 119 Orange - (Orange & White) Green - (Green & White) Brown - (Brown & White) RJ45-2 Blue - (Blue & White) (Orange) Orange - (Orange & White) RJ45-3 Blue - (Blue & White) (Green) Orange - (Orange & White) Matrix ETERNITY Quick Start...
  • Page 120 Orange - (Orange & White) Green - (Green & White) Brown - (Brown & White) RJ45-2 Blue - (Blue & White) (Orange) Orange - (Orange & White) RJ45-3 Blue - (Blue & White) (Green) Orange - (Orange & White) Matrix ETERNITY Quick Start...
  • Page 121 Orange - (Orange & White) Green - (Green & White) Brown - (Brown & White) RJ45-2 Blue - (Blue & White) (Orange) Orange - (Orange & White) RJ45-3 Blue - (Blue & White) (Green) Orange - (Orange & White) Matrix ETERNITY Quick Start...
  • Page 122 Not Connected Not Connected Brown RJ45-3 DOP-3 Relay A Orange-White (Green) Relay B Orange Door Phone-3 Status Green-White MIC Input Blue Speaker Output Blue-White Analog Ground Green Not Connected Not Connected Brown-White Not Connected Not Connected Brown Matrix ETERNITY Quick Start...
  • Page 123 Matrix ETERNITY Quick Start...
  • Page 124 MATRIX COMSEC PVT. LTD. Corporate Office: 394-GIDC, Makarpura, Vadodara - 390010, India. Tel.:+91 265 2630555, Fax: +91 265 2636598 E-mail: Info@MatrixComSec.com Factory: 39-GIDC, Waghodia - 391760, Dist. Vadodara, India. Tel.: +91 2668 262056/57 Technical Support: Tel.: +91 2668 263172/73, Fax: +91 2668 262631 E-mail: Support@MatrixComSec.com...

This manual is also suitable for:

Eternity peEternity ge