Station is the software port number of the station from 00 to 07.
Code
Loop Current (in mA)
0
25
1
30
2
35
3
40
Default is 25mA
•
To configure the same Loop Current for all stations at once, dial,
4116-*-Code
•
To configure the Loop Length for a station, dial,
4117-1-Station-Code
Where,
Station is the software port number of the station from 00 to 07.
Code
Loop Length
1
Up to 5km (16404 ft.)
2
Above 5km (16404 ft.)
Default is Up to 5km (16404 ft.)
•
To configure the same Loop Length for all stations at once, dial,
4117-*-Code
•
To configure the Minimum Current for Off-hook Detection for a station, dial,
4118-1-Station-Code
Where,
Station is the software port number of the station from 00 to 07.
Minimum Current for Off-hook
Code
Detection (in mA)
1
2
3
4
5
Default is 2 (12mA)
•
To configure the same Minimum Current for Off-hook Detection for all stations at once, dial,
4118-*-Code
•
To configure the On-hook Detection Current or lower for a station, dial,
4119-1-Station-Code
Where,
Station is the software port number of the station from 00 to 07.
On-hook Detection Current
Code
or lower (in mA)
0
1
45
10
12
14
16
18
10
12
Matrix VISIONPRO System Manual