How to configure
To configure,
•
Enter SE mode.
•
To enable/disable a trunk, dial,
3101-1-Trunk-Code
Where,
Trunk is the software port number from 0 to 2.
Code
Meaning
0
Trunk Port disabled
1
Trunk Port enabled
By default, all trunks are enabled.
•
To enable/disable all the trunks, dial,
3101-*-Code
Example:
To disable trunk2, dial, 3101-1-2-0
•
To configure the dial type of a trunk, dial,
3102-1-Trunk-Code
Where,
Trunk is the software port number from 0 to 2.
Code
Meaning
0
Pulse Type
1
Tone Type
By default, all trunks are programmed as Tone type.
•
To configure the same dial type for all the trunks, dial,
3102-*-Code
Example:
Program trunk2 with Pulse dialing.
Solution. Dial, 3102-1-2-0
•
To define a trunk type, dial,
3103-1-Trunk-Code
Where,
Trunk is the software port number from 0 to 2.
Code
Meaning
0
Normal Dial Type
1
Delayed Hotline Type
2
Hotline Type