To configure the system in Manual/Auto mode, dial,
1051-Code
Where,
Code Meaning
0
Manual Day-Night Mode
1
Auto Day-Night Mode
By default, the system is in Auto Day-Night Mode.
Example:
Program the system in Auto Day-Night mode.
Solution. Dial 1051-1
If Manual mode is selected, to set the Day or Night mode (can be done from SA mode as well), dial,
1052-Code
Where,
Code Meaning
0
Night Mode
1
Day Mode
Example:
Set system in Day mode.
Solution. Dial 1052-1
To configure the time table, dial,
1053-Day Code-Start Time-End Time
Where,
Day
Sun
Mon
Code
1
2
Start Time: Working Hours Start Time in two digits and in 24 hours Hour:Minute format.
End Time: Working Hours End Time in two digits and in 24 hours Hour:Minute format.
The left over time is taken as Night time (Non-Working Hours). Hence Night time need not be programmed.
Exit SE mode.
Example:
Program a time table with normal office hours from 08:30 to 17:00 hours from Monday to Saturday. Sunday is a
Holiday. Set the time table in Auto mode.
Solution. Dial the following commands in SE mode,
1053-1-0000-0000
1053-2-0830-1700
1053-3-0830-1700
1053-4-0830-1700
1053-5-0830-1700
1053-6-0830-1700
1053-7-0830-1700