Trunk is the software port number from 0 to 2.
Flag
0
Current limiting mode disabled
1
Current limiting mode enabled
Default code is 1.
To configure the same Current Limiting Mode for all trunks, dial,
3128-*-Flag
To configure the Minimum Loop Current for a trunk, dial,
3129-1-Trunk-Code
Where,
Trunk is the software port number from 0 to 2.
Minimum Loop
Code
Current (in mA)
0
10
1
12
2
14
3
16
Default code is 0.
To configure the same Minimum Loop Current for all trunks, dial,
3129-*-Code
To configure the TIP-RING Voltage for a trunk, dial,
3130-1-Trunk-Code
Where,
Trunk is the software port number from 0 to 2.
TIP-RING Voltage
Code
(in Volts)
0
3.1
1
3.2
2
3.35
3
3.5
Default code is 3.
To configure the same TIP-RING Voltage for all trunks, dial,
3130-*-Code
To configure the Ringer Impedance for a trunk, dial,
3131-1-Trunk-Code