Matrix Visionpro System Manual page 50

Hide thumbs Also See for Visionpro:
Table of Contents

Advertisement

Default is None
To configure the same Answer Signaling for all stations at once, dial,
4111-*-Code
To configure the Disconnect Signaling for a station, dial,
4112-1-Station-Code
Where,
Station is the software port number of the station from 00 to 07.
Code
Disconnect Signal
0
None
1
Polarity Reversal
2
Open Loop
Default is None
To configure the same Disconnect Signaling for all stations at once, dial,
4112-*-Code
To configure the Open Loop Disconnect Timer for a station, dial,
4113-1-Station-Code
Where,
Station is the software port number of the station from 00 to 07.
Open Loop Disconnect
Code
Timer (in ms)
01
68
02
136
03
204
04
272
05
340
06
408
07
476
08
544
09
612
10
680
11
748
12
816
13
884
14
952
Default is 7 (476ms)
To configure the same Open Loop Disconnect Timer for all stations at once, dial,
4113-*-Code
To configure the Loop Current for a station, dial,
4116-1-Station-Code
Where,