Matrix Visionpro System Manual page 164

Hide thumbs Also See for Visionpro:
Table of Contents

Advertisement

To configure the DID parameters,
Enter SE mode.
To activate/deactivate DID on a trunk during Day time, dial,
3501-1-Trunk-Code
Where,
Trunk is the software port from 0 to 2.
Code Meaning
0
DID deactivated
1
DID activated
To activate/deactivate DID on all trunks during Day time, dial,
3501-*-Code
To activate/deactivate DID on a trunk during Night time, dial,
3502-1-Trunk-Code
Where,
Trunk is the software port from 0 to 2.
Code Meaning
0
DID deactivated
1
DID activated
To activate/deactivate DID on all trunks during Night time, dial,
3502-*-Code
To activate/deactivate Voice Guidance for DID on a trunk during Day time, dial,
3503-1-Trunk-Code
Where,
Trunk is the software port from 0 to 2.
Code Meaning
0
Voice Guidance for DID deactivated
1
Voice Guidance for DID activated
To activate/deactivate Voice Guidance for DID on all trunks during Day time, dial,
3503-*-Code
To activate/deactivate Voice Guidance for DID on a trunk during Night time, dial,
3504-1-Trunk-Code
Where,
Trunk is the software port from 0 to 2.
Code Meaning
0
Voice Guidance for DID deactivated
1
Voice Guidance for DID activated
To activate/deactivate Voice Guidance for DID on all trunks during Night time, dial,
3504-*-Code
By default, Voice Guidance for DID is ON on all trunks during Day time and Night time.
To set the various timers related to DID, dial commands as displayed in the following table.
Matrix VISIONPRO System Manual
158

Hide quick links:

Advertisement

Table of Contents
loading