Default code is 2.
To configure the same DTMF Detection Minimum ON Timer for all trunks, dial,
3119-*-Code
To configure the DTMF Detection Minimum OFF Timer for a trunk, dial,
3120-1-Trunk-Code
Where,
Trunk is the software port number from 0 to 2.
Code
Minimum OFF Timer
01
17 ms
02
34 ms
03
51 ms
04
68 ms
05
85 ms
06
102 ms
07
119 ms
08
136 ms
09
153 ms
10
170 ms
11
187 ms
12
204 ms
Default code is 4.
To configure the same DTMF Detection Minimum OFF Timer for all trunks, dial,
3120-*-Code
To configure the DTMF Outdial ON Time for a trunk, dial,
3121-1-Trunk-Code
Where,
Trunk is the software port number from 0 to 2.
Code
DTMF ON Time
01
51 ms
02
68 ms
03
85 ms
04
102 ms
05
119 ms
06
136 ms
07
153 ms
08
170 ms
Matrix VISIONPRO System Manual