Half-Duplex to Full-Duplex Converter Environmental Data and Standards

Table 288: Environmental Data
Environmental conditions
Table 289: Safety Standards
North American ITE
European/International ITE
EMI/EMC Standards
International EMC
Certifications
IEEE 802.3 Media Access
Standards
Environmental specifications EN/ETSI 300 019-2-1 v2.1.2 - Class 1.2 Storage
452 ExtremeSwitching Hardware Installation Guide
Operating temperature: -40°C to 70°C (-40°F to 158°F)
Storage temperature: 0°C to 40°C (32°F to 104°F)
Humidity: 10% to 95% relative humidity, non-condensing
Altitude: 0 to 2,000 meters (6,562 feet)
Packaged shock (half sine): 180 m/s2 (18 G), 6 ms, 600 shocks
Packaged vibration: 5 to 62 Hz at velocity 5 mm/s, 62 to 500 Hz at 0.2
G
Packaged random vibration: 5 to 20 Hz at 1.0 ASD w/–3 dB/oct. from
20 to 200 Hz
Packaged drop height: 14 drops minimum on sides and corners at 42
inches (<15 kg box)
UL 60950-1 2nd Ed., Listed Device (U.S.)
CSA 22.2 #60950-1-03 2nd Ed. (Canada)
Complies with FCC 21CFR 1040.10 (U.S. Laser Safety)
EN 60950-1:2007 2nd Ed.
CB Report & Certificate per IEC 60950-1 2nd Ed. + National Differences
AS/NZS 60950-1 (Australia /New Zealand)
FCC CFR 47 part 15 Class A (USA)
ICES-003 Class A (Canada)
EN 55022: Class A
EN 55024:A2 Class A includes IEC 61000-4-2, 3, 4, 5, 6, 11
EN 61000-3-2,8 (Harmonics)
EN 61000-3-3 (Flicker)
2014/30/EU EMC Directive
CISPR 22: Ed 5.2, Class A (International Emissions)
CISPR 24:A2: Class A (International Immunity)
IEC 61000-4-2: EN 61000-4-2:2009 Electrostatic Discharge, 8kV
Contact, 15 kV Air, Criteria A
IEC 61000-4-3: EN 61000-4-3:2006+A1:2008 Radiated Immunity
10V/m, Criteria A
IEC 61000-4-4: am1 ed.2./EN 61000-4-4:2004/A1:2010 Transient Burst,
1 kV, Criteria A
IEC 61000-4-5: EN 61000-4-5:2006 Surge, 2 kV L-L, 2 kV L-G, Level 3,
Criteria A
IEC 61000-4-6: EN 61000-4-6:2009 Conducted Immunity, 0.15-80
MHz, 10V/m unmod. RMS, Criteria A
IEC/EN 61000-4-11: Power Dips & Interruptions, >30%, 25 periods,
Criteria C
IEEE 802.3ab 1000BASE-T
IEEE 802.az EEE
EN/ETSI 300 019-2-2 v2.1.2 - Class 2.3 Transportation
EN/ETSI 300 019-2-3 v2.1.2 - Class 3.1e Operational
ASTM D3580 Random Vibration Unpackaged 1.5 G