Extreme Networks ExtremeSwitching X435 Series Hardware Installation Manual page 200

For switches using extremexos version 30
Table of Contents

Advertisement

Stacking Considerations for Each Switch Model
Table 84: Alternate Stacking Ports for X460-G2 Switches (continued)
Switch Model
X460-G2-24t-10GE4
X460-G2-24x-10GE4
X460-G2-24p-10GE4
X460-G2-48t-10GE4
X460-G2-48x-10GE4
X460-G2-48p-10GE4
Note
Additional Stacking Considerations for X460-G2 Switches
When planning to use X460-G2 switches in a stack, note the following additional considerations:
When using the VIM-2ss module, you can enable stacking without enabling stacking-support
because the ports are native to the switch. All other VIMs require stacking-support to be enabled.
The X460-G2 switch has "protocol enhanced" set by default. (Older switches, such as the X460,
have "protocol standard" set by default. When you add a switch to a stack, make sure the new
switch has "protocol enhanced" set so that it can communicate with the X460-G2 switch and the
other switches in the stack.)
See also
See also
201.
Summit X460-G2 (10G Models) Stack Configuration Guidelines
Before deploying a new stack with Summit X460-G2 10-gigabit switch models (10GE4), consider the
following guidelines:
In a stack that contains X460-G2 switches and other switch models, the X460-G2 switch might
provide more memory and more features than the other switch models. Take this into account when
you decide which switches will serve as the master and backup nodes, and when you configure
failover operation.
To use the failover feature in the stack, a second Summit X460-G2 switch is recommended. It must
be the backup node.
X460-G2 (10GE4) switches support SummitStack-V stacking on front panel 10G SFP+ ports, as well
as native stacking through an attached VIM-2q or VIM-2ss module.
200 ExtremeSwitching Hardware Installation Guide
Type or location of Native
Stacking Ports
VIM-2ss or VIM-2q
VIM-2ss or VIM-2q
On X460-G2 24-port 10GE4 switches, ports 31 and 32 are not available as data ports when
the alternate stacking ports are used.
On X460-G2 48-port 10GE4 switches, ports 51 and 52 are not available as data ports when
the alternate stacking ports are used.
Summit X460-G2 (10G Models) Stack Configuration Guidelines
Summit X460-G2 (1G Models Using VIM Ports) Stack Configuration Guidelines
Alternate Stacking
Location of Alternate
Ports
Stacking Ports
31,32
Front panel
51,52
Front panel
on page 200.
Building Stacks
on page

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ExtremeSwitching X435 Series and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Extremeswitching x440-g2 seriesExtremeswitching x450-g2 seriesExtremeswitching x460-g2 seriesExtremeswitching x465 seriesExtremeswitching x590 seriesExtremeswitching x620 series ... Show all

Table of Contents