Logging in for the First Time

Each switch should be connected to a management console – a terminal or PC with terminal-emulation
software. For all Extreme Networks switches, the terminal or PC must be configured with the following
settings:
Baud rate: 115200 (for X465, X590, X690, or X870) or 9600 (for other models) (see note)
Data bits: 8
Stop bit: 1
Parity: None
Flow control: XON/XOFF
Note
Set the baud rate to 115200 when using the RJ45 Ethernet management port on an X465,
X590, X690 or X870 series switch.
For information about setting the proper values, refer to the documentation supplied with the terminal
or PC.
Ensure that the connection between the switch and the management console is over either an RJ45-to-
serial adapter or a DB9 serial cable. Appropriate cables are available from your local supplier, or you can
make your own. To ensure the electromagnetic compatibility of the unit, use only shielded serial cables.
For connector pinouts associated with the console port, see
Logging in for the First Time
After your switch has completed all power-on self-tests, it is operational. Before logging in, verify that
the switch LEDs are on (solid green or blinking green) and that it is connected to a management
console as described in
To perform the initial login and complete initial configuration tasks, follow these steps.
1. Using a terminal emulator such as PuTTY or TeraTerm, connect to the switch using the serial port
connection.
Be sure that your serial connection is set properly:
Baud rate: Baud rate: 115200 (for X465, X590, X690, or X870) or 9600 (for other models) (see
note)
Data bits: 8
Stop bit: 1
2. At the management console, press [Enter] one or more times until you see the login prompt.
260 ExtremeSwitching Hardware Installation Guide
Connecting a Switch to the Management Console
Note
Set the baud rate to 115200 when using the RJ45 Ethernet management port on an X465,
X590, X690 or X870 series switch.
Installing Your Extreme Networks Switch
Console Connector Pinouts
on page 259.
on page 475.