Digital Inputs And Outputs Of The System Input/Output (Sio) Module; Input Signals; Table 3-2 Dio Input Specifications (Sio Module) On The Security Panel - adept technology 550 Instruction Handbook Manual

Hide thumbs Also See for 550:
Table of Contents

Advertisement

Digital Inputs and Outputs of the System Input/Output (SIO) Module

The Digital I/O connector on the SIO is a 50-pin, high-density, D-Sub female connector for
digital I/O communication. There are 12 input channels and 8 output channels. All
channels are opto-isolated. The same connector also provides access to the Emergency
Stop circuit (E-Stop input and Passive E-Stop output). To access this connector, you will
need a cable with a male 50-pin, D-Sub connector at one end (not supplied with the
system.)

Input Signals

The digital I/O connector handles input signals 1001 to 1012. Each channel has an input
and a corresponding return line. Refer to Table 3-2 for input specifications. The locations
of the signals on the connector are shown in Table 3-4.
Table 3-2. DIO Input Specifications (SIO module)
Operational voltage range
"Off" state voltage range
"On" state voltage range
Typical threshold voltage
Operational current range
a
"Off" state current range
a
"On" state current range
Typical threshold current, per channel
Impedance (V
/I
)
in
in
Current at V
= +24 VDC
in
Turn on response time (hardware)
Software scan rate/response time
Turn off response time (hardware)
Software scan rate/response time
a
the input current specifications are provided for reference; voltage sources
are typically used to drive the inputs.
b
2 ms response time (minimum) for fast inputs 1001 to 1003, depending on
program task configuration, when used with V
Adept 550 Robot Instruction Handbook, Rev A
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
0 to 24 VDC
0 to 3 VDC
10 to 24 VDC
V
in
a
0 to 20 mA
0 to 1.2 mA
7 to 20 mA
a
10 mA
1.3 KΩ minimum
I
in
5 µsec maximum
16 ms scan cycle/ 32 ms max
response time
5 µsec maximum
16 ms scan cycle/ 32 ms max
response time
+
INT.EVENT instruction.
Overview of Safety System
= 8 VDC
≤20 mA
b
b
53