Chapter 3 - Preparation for Safe and Effective Use of the Robot

Output Signals

The digital I/O connector handles output signals 0001 to 0008. Refer to Table 3-3 for
output specifications. The locations of the signals on the connector are shown in Table 3-4.
The SIO provides separate + and – connections for each channel (no internal common
connections.) This allows you the choice to wire for current-sourcing or current-sinking
mode as required.
Each output channel (circuit) should be connected to only one output device. Each output
circuit is short-circuit protected.
Table 3-3. DIO Output Specifications (SIO module)
Operating voltage range
Operational current range, per channel
V
across output in on condition
drop
Output off leakage current
Turn on response time (hardware)
Software scan rate/response time
Turn off response time (hardware)
Software scan rate/response time
CAUTION: The above specifications for the digital inputs and outputs on
the SIO module are different than the specifications for a DIO module.
!
Specifically, the SIO output current is limited to 100 mA per channel,
whereas the DIO output is rated at 400 mA.
54
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Adept 550 Robot Instruction Handbook, Rev A
0 to 24 VDC
≤ 100 mA
I
out
≤ 0.85 V at 100 mA
V
drop
≤ 0.80 V at 10 mA
V
drop
≤ 600 µA
I
out
3 µsec maximum
16 ms scan cycle/ 32 ms max
response time
200 µsec maximum
16 ms scan cycle/ 32 ms max
response time