Connecting the MCP to the VFP

The MCP is connected to the system at the Pendant connector on the VFP (see
Figure 2-14). See Chapter 4 for instructions on using the MCP.
Install the MCP to the connector that is marked
WARNING: The VFP has two keyswitches. One to select the device that
controls program execution and one to select the operating mode. Before
!
it is possible to use the MCP in the workcell, the operating keyswitch
must be set to
program execution from being started from the keyboard or terminal.
CAUTION: The coiled cable on the MCP III has been tested to withstand
500 V of repetitive electrical bursts per EN61000-4-4. Exposing the MCP
!
to voltages higher than 500 V may cause the robot to shut down. In this
event, it may be necessary to unplug, then reconnect, the MCP to restart
the robot.

MCP Cradle

The MCP is stored in the MCP cradle when it is not being held by an operator. The cradle
has a retaining clip that keeps the Hold-to-Run switch closed. The MCP cradle must be
installed outside of the robot workcell. See Figure 6-9 on page 90 for the dimensions of the
cradle.
Adept 550 Robot Instruction Handbook, Rev A
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
PENDANT
and the other one to
MANUAL
External Front Panel (VFP)
SYSTEM
LAMP
MANUAL
AUTO
POWER
TEST
O
®
PROGRAM
PENDANT
LOCAL
NETWORK
START
MCP Bypass Plug,
Install if no MCP
- +
1
2
3
Figure 2-14. MCP Connection
Signal Interconnection Installation
on the VFP.
. This will prevent
LOCAL
HIGH POWER
ON/OFF
I
EMERGENCY STOP
PROGRAM
RUNNING
Manual
Control
Pendant
35