p10062
SI password new TM54F / SI password new
TM54F_MA,
Can be changed: C2
TM54F_SL
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
0000 hex
Description:
Enters the new Safety Integrated password for the Terminal Module 54F (TM54F).
Dependency:
A change made to the Safety Integrated password must be acknowledged in the following parameter:
Refer to: p10063
p10063
SI password acknowledgement TM54F / SI ackn password
TM54F_MA,
Can be changed: C2
TM54F_SL
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
0000 hex
Description:
Acknowledgement of the new Safety Integrated password for the Terminal Module 54F (TM54F).
Dependency:
Refer to: p10062
Note:
The new password entered into p10062 must be re-entered in order to acknowledge.
p10062 = p10063 = 0 is automatically set after the new Safety Integrated password has been successfully acknowl-
edged.
r10090[0...2]
SI TM54F version / SI TM54F version
TM54F_MA,
Can be changed: -
TM54F_SL
Data type: Unsigned16
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Displays the Safety Integrated version for the Terminal Module 54F (TM54F).
Index:
[0] = Safety Version (major release)
[1] = Safety Version (minor release)
[2] = Safety Version (baselevel or patch)
Dependency:
Refer to: r9390, r9590, r9770, r9870, r9890
Note:
Example:
r10090[0] = 2, r10090[1] = 3, r10090[2] = 1 --> SI version V02.03.01
r61000[0...239]
PROFINET Name of Station / PN Name of Station
CU_S (PROFINET)
Can be changed: -
Data type: Unsigned8
P-Group: -
Not for motor type: -
Min
-
Description:
Displays PROFINET Name of Station.
Notice:
An ASCII table (excerpt) can be found, for example, in the following List Manual:
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Calculated: -
Dynamic index: -
Units group: -
Max
FFFF FFFF hex
Calculated: -
Dynamic index: -
Units group: -
Max
FFFF FFFF hex
Calculated: -
Dynamic index: -
Units group: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Max
-
Parameters
List of parameters
Access level: 3
Func. diagram: 2846
Unit selection: -
Expert list: 1
Factory setting
0000 hex
Access level: 3
Func. diagram: 2846
Unit selection: -
Expert list: 1
Factory setting
0000 hex
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
1-1067