List of parameters
Index:
[0] = Safety Version (major release)
[1] = Safety Version (minor release)
[2] = Safety Version (baselevel or patch)
Dependency:
Refer to: r9770, r9870, r9890
Note:
Example:
r9590[0] = 2, r9590[1] = 3, r9590[2] = 1 --> SI motion version V02.03.01
p9601
SI enable, functions integrated in the drive (Control Unit) / SI enable fct CU
SERVO, VECTOR
Can be changed: C2
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Sets the enable signals for safety functions on the Control Unit that are integrated in the drive.
Bit field:
Bit
Signal name
00
Enable STO (SH) via terminals (Control
Unit)
02
Motion monitoring functions integr. in the
drive (Control Unit)
03
Enable PROFIsafe (Control Unit)
Dependency:
Refer to: p9801
Note:
For p9601.2 = 1 and p9601.3 = 0 the following apply:
It is assumed that the motion monitoring functions integrated in the drive are controlled via the Terminal Module 54F
(TM54F).
CU: Control Unit
STO: Safe Torque Off / SH: Safe standstill
SI: Safety Integrated
SMM: Safe Motion Monitoring
p9602
SI enable Safe Brake Control (Control Unit) / SI enable SBC CU
SERVO, VECTOR
Can be changed: C2
Data type: Integer16
P-Group: Safety Integrated
Not for motor type: -
Min
0
Description:
Sets the enable signal for the function "Safe Brake Control" (SBC) on the Control Unit.
Values:
0:
1:
Dependency:
Refer to: p9802
Note:
The "Safe Brake Control" function is not activated until at least one safety monitoring function has been enabled
(i.e. p9501 not equal to 0 and/or p9601 not equal to 0).
The parameterization "no motor holding brake available" and "Safe Brake Control" enabled (p1215 = 0, p9602 =
p9802 = 1) is not practical if there is no motor holding brake.
The parameterization "motor holding brake the same as sequence control, connection via BICO" and "Safe Brake
Control" enabled (p1215 = 3, p9602 = 1, p9802 = 1) is not practical.
It is not permissible to parameterize "motor holding brake without feedback signals" and also enable "safe brake
control" (p1278 = 1, p9602 = 1, p9802 = 1).
CU: Control Unit
SBC: Safe Brake Control
SI: Safety Integrated
1-1016
Inhibit SBC
Enable SBC
Calculated: -
Dynamic index: -
Units group: -
Max
-
1 signal
Enable
Enable
Enable
Calculated: -
Dynamic index: -
Units group: -
Max
1
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 bin
0 signal
FP
Inhibit
2810
Inhibit
-
Inhibit
-
Access level: 3
Func. diagram: 2814
Unit selection: -
Expert list: 1
Factory setting
0