Parameters
List of parameters
p9555
SI motion transition time STOP F to STOP B (Control Unit) / SI Mtn t F->B CU
SERVO, VECTOR
Can be changed: C2
Data type: Floating Point
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [ms]
Description:
Sets the transition time from STOP F to STOP B.
Dependency:
Refer to: C01711
Note:
A change only becomes effective after a POWER ON.
p9556
SI motion pulse cancelation delay time (Control Unit) / SI Mtn IL t_del CU
SERVO, VECTOR
Can be changed: C2
Data type: Floating Point
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [ms]
Description:
Sets the delay time for the safe pulse cancelation after STOP B.
Dependency:
Refer to: p9560
Refer to: C01701
Note:
A change only becomes effective after a POWER ON.
p9557
SI motion pulse cancelation test time (Control Unit) / SI Mtn IL t_test
SERVO, VECTOR
Can be changed: C2
Data type: Floating Point
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [ms]
Description:
Sets the time after which the pulses must have been canceled when initiating the test stop.
Dependency:
Refer to: C01798
Note:
A change only becomes effective after a POWER ON.
p9558
SI motion acceptance test mode time limit (Control Unit) / SI Mtn t accept
SERVO, VECTOR
Can be changed: C2
Data type: Floating Point
P-Group: Safety Integrated
Not for motor type: -
Min
5000.00 [ms]
Description:
Sets the maximum time for the acceptance test mode.
If the acceptance test mode takes longer than the selected time limit, then the mode is automatically terminated.
Dependency:
Refer to: C01799
Note:
A change only becomes effective after a POWER ON.
1-1012
Calculated: -
Dynamic index: -
Units group: -
Max
600000.00 [ms]
Calculated: -
Dynamic index: -
Units group: -
Max
600000.00 [ms]
Calculated: -
Dynamic index: -
Units group: -
Max
10000.00 [ms]
Calculated: -
Dynamic index: -
Units group: -
Max
100000.00 [ms]
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Access level: 3
Func. diagram: 2825
Unit selection: -
Expert list: 1
Factory setting
0.00 [ms]
Access level: 3
Func. diagram: 2825
Unit selection: -
Expert list: 1
Factory setting
100.00 [ms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
100.00 [ms]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
40000.00 [ms]