Parameters
List of parameters
p9535[0...1]
SI motion SLP (SE) lower limit values (Control Unit) / SI Mtn SLP low lim
SERVO, VECTOR
Can be changed: U, T
Data type: Floating Point
P-Group: Safety Integrated
Not for motor type: -
Min
-2147000.000 [mm]
Description:
Sets the lower limit for the function "Safely-Limited Position" (SLP).
Index:
[0] = Limit value SLP1 (SE1)
[1] = Limit value SLP2 (SE2)
Dependency:
Refer to: p9501, p9534, p9562
Note:
For the setting of these limit values, the following applies: p9534 > p9535
A change only becomes effective after a POWER ON.
SLP: Safely-Limited Position / SE: Safe software limit switches
p9535[0...1]
SI motion SLP (SE) lower limit values (Control Unit) / SI Mtn SLP low lim
SERVO (Safety rot),
Can be changed: U, T
VECTOR (Safety rot)
Data type: Floating Point
P-Group: Safety Integrated
Not for motor type: -
Min
-2147000.000 [°]
Description:
Sets the lower limit for the function "Safely-Limited Position" (SLP).
Index:
[0] = Limit value SLP1 (SE1)
[1] = Limit value SLP2 (SE2)
Dependency:
Refer to: p9501, p9534, p9562
Note:
For the setting of these limit values, the following applies: p9534 > p9535
A change only becomes effective after a POWER ON.
SLP: Safely-Limited Position / SE: Safe software limit switches
p9536[0...29]
SI motion SCA (SN) plus cam position (Control Unit) / SI Mtn SCA+
SERVO, VECTOR
Can be changed: U, T
Data type: Floating Point
P-Group: Safety Integrated
Not for motor type: -
Min
-2147000.000 [mm]
Description:
Sets the plus cam position for the function "Safe Cam" (SCA).
Index:
[0] = Cam position SCA1 (SN1)
[1] = Cam position SCA2 (SN2)
[2] = Cam position SCA3 (SN3)
[3] = Cam position SCA4 (SN4)
[4] = Cam position SCA5 (SN5)
[5] = Cam position SCA6 (SN6)
[6] = Cam position SCA7 (SN7)
[7] = Cam position SCA8 (SN8)
[8] = Cam position SCA9 (SN9)
[9] = Cam position SCA10 (SN10)
[10] = Cam position SCA11 (SN11)
[11] = Cam position SCA12 (SN12)
[12] = Cam position SCA13 (SN13)
[13] = Cam position SCA14 (SN14)
[14] = Cam position SCA15 (SN15)
1-1002
Calculated: -
Dynamic index: -
Units group: -
Max
2147000.000 [mm]
Calculated: -
Dynamic index: -
Units group: -
Max
2147000.000 [°]
Calculated: -
Dynamic index: -
Units group: -
Max
2147000.000 [mm]
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-100000.000 [mm]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-100000.000 [°]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
10.000 [mm]