p9559
SI motion forced checking procedure timer (Control Unit) / SI Mtn dyn timer
SERVO, VECTOR
Can be changed: C2
Data type: Floating Point
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [h]
Description:
Sets the time to carry out the forced checking procedure and test the safety motion monitoring functions integrated
in the drives.
Within the parameterized time, the safety functions must have been tested at least once including de-selecting the
function "Safe Torque Off". The monitoring time is reset each time that the test is carried out.
The signal source to initiate the forced checking procedure is parameterized in p9705.
Dependency:
Refer to: p9705
Refer to: C01798
Note:
A change only becomes effective after a POWER ON.
p9560
SI motion pulse cancelation shutdown velocity (Control Unit) / SI Mtn IL v_shutCU
SERVO, VECTOR
Can be changed: C2
Data type: Floating Point
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [mm/min]
Description:
Sets the shutdown velocity for pulse cancelation.
Below this velocity "standstill" is assumed and for STOP B, the pulses are canceled (by changing to STOP A).
Dependency:
Refer to: p9556
Note:
A change only becomes effective after a POWER ON.
p9560
SI motion pulse cancelation shutdown speed (Control Unit) / SI Mtn IL n_shutCU
SERVO (Safety rot),
Can be changed: C2
VECTOR (Safety rot)
Data type: Floating Point
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [RPM]
Description:
Sets the shutdown speed for the pulse cancelation.
Below this speed "standstill" is assumed and for STOP B, the pulses are canceled (by changing to STOP A).
Dependency:
Refer to: p9556
Note:
A change only becomes effective after a POWER ON.
p9561
SI motion SLS (SG) stop response (Control Unit) / SI Mtn SLS resp
SERVO, VECTOR
Can be changed: U, T
Data type: Integer16
P-Group: Safety Integrated
Not for motor type: -
Min
0
Description:
Sets the stop response for the function "Safely-Limited Speed" (SLS).
This setting applies for all SLS limit values.
An input value of less than 5 signifies personnel protection, from 10 and upwards, machine protection.
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Calculated: -
Dynamic index: -
Units group: -
Max
9000.00 [h]
Calculated: -
Dynamic index: -
Units group: -
Max
6000.00 [mm/min]
Calculated: -
Dynamic index: -
Units group: -
Max
6000.00 [RPM]
Calculated: -
Dynamic index: -
Units group: -
Max
14
Parameters
List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
8.00 [h]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.00 [mm/min]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0.00 [RPM]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
5
1-1013

Advertisement

Table of Contents
loading

Table of Contents