From speed signals [8010.4]
From speed signals [8010.8]
From speed signals [8010.4]
From speed signals [8010.8]
<1> n
= smoothed speed actual value r2169 [8010.2].
act
1
2
DO: SERVO, VECTOR, VECTORMV
Internal control/status words - Status word, monitoring functions 1
Bit No.
Status word, monitoring functions 1
0
Reserved
1
|n_act| <= speed threshold value 2 (p2155)
1
2
|n_act| > speed threshold value 2 (p2155)
3
1 = n_act >= 0
4
Reserved
5
Reserved
6
n_act > n_max
7
1 = Speed setpoint - actual value deviation within tolerance t_off
8
Reserved
9
Reserved
10
Reserved
3
4
<1>
r2197.1
<1>
r2197.2
r2197.3
r2197.6
r2197.7
5
6
Function diagram
fp_2534_51_eng.vsd
SINAMICS
31.05.06 V02.05.00
p0115[3]
ZSW monitoring functions 1
r2197
7
8