Siemens SINAMICS S Series List Manual page 919

Hide thumbs Also See for SINAMICS S Series:
Table of Contents

Advertisement

0: There are not parameter changes to save.
1: There are parameter changes to save.
Index 8:
Drive object changeover of units. When changing reference or changeover parameters (e.g. p2000, p0304 ...), the
value in this index is incremented.
Index 9:
Drive object parameter count. When changing the number of parameters by loading Drive Control Chart (DCC), the
value in this index is incremented.
Index:
[0] = Sum of the following indices
[1] = r0107 or r0108
[2] = Drive object name (p0199)
[3] = Structure-relevant parameters (e.g. p0180)
[4] = BICO interconnections
[5] = Activate/de-activate drive object
[6] = Data back-up required
[7] = Reserved
[8] = Reference or changeover parameters (e.g. p2000)
[9] = Parameter count through Drive Control Chart (DCC)
Dependency:
Refer to: r7868, r7870
r7871[0...9]
Configuration changes drive object / Config_chng DO
A_INF, B_INF,
Can be changed: -
S_INF
Data type: Unsigned32
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the configuration changes on the drive object.
Index 0:
When changing one of the following indices, then the value in this index is incremented.
Index 1:
Drive object configuration. When changing p10, p0107 or p108, the value in this index is incremented.
Index 2:
Drive object name. When changing p0199, the value in this index is incremented.
Index 3:
Drive object structure. When changing a parameter that is relevant for the structure (e.g. number of data sets), the
value in this index is incremented.
Index 4:
Drive object BICO interconnections. When changing r3977, the value in this index is incremented.
Index 6:
Drive object, data save.
0: There are not parameter changes to save.
1: There are parameter changes to save.
Index 8:
Drive object changeover of units. When changing reference or changeover parameters (e.g. p2000, p0304 ...), the
value in this index is incremented.
Index 9:
Drive object parameter count. When changing the number of parameters by loading Drive Control Chart (DCC), the
value in this index is incremented.
Index:
[0] = Sum of the following indices
[1] = p0010, r0107 or r0108
[2] = Drive object name (p0199)
[3] = Structure-relevant parameters (e.g. p0180)
[4] = BICO interconnections
[5] = Activate/de-activate drive object
[6] = Data back-up required
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Calculated: -
Dynamic index: -
Units group: -
Max
-
Parameters
List of parameters
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
1-919

Advertisement

Table of Contents
loading

Table of Contents