[3] = Drive group 4
Bit field:
Bit
Signal name
00
Power_removed
01
SS1_active
02
SS2_active
03
SOS_active
04
SLS_active
Note:
Bit = 0 signal --> not selected
Bit = 1 signal --> selected
The selected signals (high-active) are OR'ed The result of the logic operation results in the status "Safe State".
p10040
SI F-DI input mode / SI F-DI inp_mode
TM54F_MA,
Can be changed: C2
TM54F_SL
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Sets the input mode for the safety-relevant input terminals of terminal series 2.
Bit field:
Bit
Signal name
00
F-DI 0, DI 1+ (X521.3)
01
F-DI 1, DI 3+ (X521.5)
02
F-DI 2, DI 5+ (X522.2)
03
F-DI 3, DI 7+ (X522.4)
04
F-DI 4, DI 9+ (X522.6)
05
F-DI 5, DI 11+ (X531.3)
06
F-DI 6, DI 13+ (X531.5)
07
F-DI 7, DI 15+ (X532.2)
08
F-DI 8, DI 17+ (X532.4)
09
F-DI 9, DI 19+ (X532.6)
Note:
Only an NC contact can be connected to terminals that are not listed in the selection.
p10041
SI F-DI enable for test / SI F-DI enab test
TM54F_MA,
Can be changed: C2
TM54F_SL
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
-
Description:
Enable signal for the integration of F-DI in the test (forced checking procedure) of the sensor power supply.
Bit field:
Bit
Signal name
00
F-DI 0, power supply L1+
01
F-DI 1, power supply L1+
02
F-DI 2, power supply L1+
03
F-DI 3, power supply L1+
04
F-DI 4, power supply L1+
05
F-DI 5, power supply L2+
06
F-DI 6, power supply L2+
07
F-DI 7, power supply L2+
08
F-DI 8, power supply L2+
09
F-DI 9, power supply L2+
Note:
F-DI: Failsafe Digital Input
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
1 signal
Selected
Selected
Selected
Selected
Selected
Calculated: -
Dynamic index: -
Units group: -
Max
-
1 signal
NO contact
NO contact
NO contact
NO contact
NO contact
NO contact
NO contact
NO contact
NO contact
NO contact
Calculated: -
Dynamic index: -
Units group: -
Max
-
1 signal
Test active
Test active
Test active
Test active
Test active
Test active
Test active
Test active
Test active
Test active
Parameters
List of parameters
0 signal
FP
Not selected
-
Not selected
-
Not selected
-
Not selected
-
Not selected
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 bin
0 signal
FP
NC contact
2850
NC contact
2850
NC contact
2850
NC contact
2850
NC contact
2850
NC contact
2851
NC contact
2851
NC contact
2851
NC contact
2851
NC contact
2851
Access level: 3
Func. diagram: 2848
Unit selection: -
Expert list: 1
Factory setting
0000 bin
0 signal
FP
No test
-
No test
-
No test
-
No test
-
No test
-
No test
-
No test
-
No test
-
No test
-
No test
-