Siemens SINAMICS S Series List Manual page 1052

Hide thumbs Also See for SINAMICS S Series:
Table of Contents

Advertisement

Parameters
List of parameters
p10014[0...5]
SI Motor Module Node Identifier Word 3 / SI MM Node ID 3
TM54F_MA,
Can be changed: C2
TM54F_SL
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
0000 hex
Description:
Sets the actual Node Identifier (word 3, bit 64 ... 95) for the Motor Modules.
Index:
[0] = Drive 1
[1] = Drive 2
[2] = Drive 3
[3] = Drive 4
[4] = Drive 5
[5] = Drive 6
Dependency:
Refer to: p10012, p10013
Note:
The complete Node Identifier (96 bit) is represented in p10012, p10013 and p10014.
p10020[0...3]
SI special operating mode selection / SI spec op sel
TM54F_MA,
Can be changed: C2
TM54F_SL
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
0
Description:
Sets the special operating mode for the operating mode "function interface".
0 = Inactive
1 = Safe Operating Stop with braking (SS2)
2 = Safe Operating Stop without braking (SOS)
3 = Safely reduced speed without standstill (SLS)
4 = Safely reduced speed with agreement (SS2 --> SLS)
Index:
[0] = Drive group 1
[1] = Drive group 2
[2] = Drive group 3
[3] = Drive group 4
Dependency:
Refer to: p10008
Note:
Parameter is being prepared - for this firmware version, the function interface is not supported.
SS2: Safe Stop 2
SOS: Safe Operating Stop
SLS: Safely-Limited Speed
p10021[0...3]
SI Emergency Stop stop response / SI Emergency Stop
TM54F_MA,
Can be changed: C2
TM54F_SL
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
0
Description:
Sets the stop response for the drive group for Emergency Stop.
The input terminal for Emergency Stop is set in p10038.
0 = Stop reaction STO
1 = Stop reaction SS1
2 = Stop reaction SS2
1-1052
Calculated: -
Dynamic index: -
Units group: -
Max
FFFF FFFF hex
Calculated: -
Dynamic index: -
Units group: -
Max
3
Calculated: -
Dynamic index: -
Units group: -
Max
2
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0000 hex
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0