Siemens SINAMICS S Series List Manual page 1045

Hide thumbs Also See for SINAMICS S Series:
Table of Contents

Advertisement

Index 0 = license key character 1 (e.g. 69 dec)
Index 1 = license key character 2 (e.g. 65 dec)
...
Index 19 = license key character 20 (e.g. 0 dec)
With the commissioning software, the ASCII characters are entered uncoded.
Dependency:
Refer to: r7843, p9921
Refer to: A13000, A13001
Notice:
An ASCII table (excerpt) can be found, for example, in the following List Manual:
Note:
Onlyy the ASCII characters, contained in a license key can be entered.
When changing p9920[x] to the value 0, all of the following indices are also set to 0.
After entering the license key, the license key must be activated (p9921).
If the licensing is not adequate, then the following alarm is displayed together with LED:
- A13000 --> licensing not sufficient
- LED READY --> flashes green/red with 0.5 Hz
p9921
Licensing, activate license key / Act license key
CU_S
Can be changed: U, T
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Activates the entered license key.
The following is executed when activating the license key.
- the checksum of the entered license key is checked.
- the entered license key is saved in the a non-volatile fashion on the CompactFlash card.
- re-enter the license key.
Values:
0:
1:
Dependency:
Refer to: p9920
Refer to: A13000, A13001
Note:
Before activation, the license key entered using parameter p9920 is checked. If this check identifies an error, acti-
vation is rejected. In this case, writing a 1 to p9921 is rejected.
When the license key has been activated, p9921 is automatically set to 0.
r9925[0...99]
CompactFlash card file error / CF file error
CU_CX32, CU_S
Can be changed: -
Data type: Unsigned8
P-Group: -
Not for motor type: -
Min
-
Description:
Displays the directory and the name of the file that was identified as illegal with respect to the state when supplied
from the factory when checking the CompactFlash card.
Dependency:
Refer to: r9926
Refer to: A01016
Note:
The directory and name of the file is displayed in the ASCII code.
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Inactive
Activate start license key
Calculated: -
Dynamic index: -
Units group: -
Max
1
Calculated: -
Dynamic index: -
Units group: -
Max
-
Parameters
List of parameters
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-