Siemens SINAMICS S Series List Manual page 1355

Hide thumbs Also See for SINAMICS S Series:
Table of Contents

Advertisement

[8832] From sequence control
[8832] From sequence control
[8832] From sequence control
[8832] From sequence control
[8832] From sequence control
Bit 9 = 1 --> Ready to exchange process data
[8850] From power unit
[8834.4] From line contactor control
<1> The master system requests process data.
1
2
DO: S_INF
Smart Infeed - Status word, sequence control infeed
Bit
Status word sequence control infeed
No.
0
1 = Ready to power-up
1
1 = Ready to operate
2
1 = Operation enabled
3
Reserved
4
1 = No OFF2 active
5
Reserved
6
1 = Power-on inhibit
7
Reserved
8
Reserved
9
1 = Control requested
<1>
10
Reserved
11
1 = Pre-charging completed
12
1 = Line contactor closed
13
Reserved
14
Reserved
15
Reserved
3
4
5
6
Function diagram
fp_8826_01_eng.vsd
SINAMICS S
19.02.07 V02.05.00
p0115[3] (2000.00 µs)
ZSW sequence ctrl
r0899
r0899.0
r0899.1
r0899.2
r0899.4
r0899.6
r0899.9
r0899.11
[8864.5]
r0899.12
7
8
- 8826 -