Siemens SINAMICS S Series List Manual page 656

Hide thumbs Also See for SINAMICS S Series:
Table of Contents

Advertisement

Parameters
List of parameters
p2614
BI: EPOS search for reference reversing cam plus / Rev plus
SERVO (EPOS),
Can be changed: T
VECTOR (EPOS)
Data type: Unsigned32 / Binary
P-Group: Basic positioner
Not for motor type: -
Min
-
Description:
Sets the signal source for the reversing cam in the negative direction of travel.
1 signal: Reversing cam not reached.
0 signal: Reversing cam reached.
Dependency:
Refer to: p2613
Note:
If, during the search for reference from the reversing cam minus and plus, a 0 signal is detected, then the axis
remains stationary (at standstill).
p2615
EPOS maximum number of traversing blocks / Trav_block qty max
SERVO (EPOS),
Can be changed: C2(17)
VECTOR (EPOS)
Data type: Unsigned8
P-Group: Basic positioner
Not for motor type: -
Min
1
Description:
Sets the maximum number of traversing blocks that are available.
Dependency:
Refer to: p2616, p2617, p2618, p2619, p2620, p2621, p2622, p2623, p2624
p2616[0...n]
EPOS traversing block, block number / Trav_blk, blkNo.
SERVO (EPOS),
Can be changed: U, T
VECTOR (EPOS)
Data type: Integer16
P-Group: Basic positioner
Not for motor type: -
Min
-1
Description:
Sets a block number.
-1: Invalid block number. These blocks are not taken into account.
0 ... 63: Valid block number.
Dependency:
The number of indices depends on p2615.
Refer to: p2615, p2617, p2618, p2619, p2620, p2621, p2622, p2623, p2624
p2617[0...n]
EPOS traversing block position / Trav_block pos
SERVO (EPOS),
Can be changed: U, T
VECTOR (EPOS)
Data type: Integer32
P-Group: Basic positioner
Not for motor type: -
Min
-2147482648 [LU]
Description:
Sets the target position for the traversing block.
Dependency:
The number of indices depends on p2615.
Refer to: p2615, p2616, p2618, p2619, p2620, p2621, p2622, p2623, p2624
Note:
The target position is approached in either relative or absolute terms depending on p2623.
1-656
Calculated: -
Dynamic index: -
Units group: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Max
64
Calculated: -
Dynamic index: p2615
Units group: -
Max
63
Calculated: -
Dynamic index: p2615
Units group: -
Max
2147482647 [LU]
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Access level: 1
Func. diagram: 3612
Unit selection: -
Expert list: 1
Factory setting
1
Access level: 1
Func. diagram: 3616
Unit selection: -
Expert list: 1
Factory setting
64
Access level: 1
Func. diagram: 3616
Unit selection: -
Expert list: 1
Factory setting
-1
Access level: 1
Func. diagram: 3616
Unit selection: -
Expert list: 1
Factory setting
0 [LU]