Siemens SINAMICS S Series List Manual page 1063

Hide thumbs Also See for SINAMICS S Series:
Table of Contents

Advertisement

p10045[0...5]
SI F-DO 3 signal sources / SI F-DO 3 S_src
TM54F_MA,
Can be changed: C2
TM54F_SL
Data type: Integer16
P-Group: Safety Integrated
Not for motor type: -
Min
0
Description:
Sets the signal sources for F-DO 3.
The 6 signal sources in p10045[0...5] are AND'ed and the result is output at F-DO 3.
Values:
0:
1:
2:
3:
4:
5:
6:
7:
8:
9:
257:
258:
259:
260:
261:
262:
263:
264:
265:
513:
514:
515:
516:
517:
518:
519:
520:
521:
769:
770:
771:
772:
773:
774:
775:
776:
777:
Index:
[0] = AND logic operation input 1
[1] = AND logic operation input 2
[2] = AND logic operation input 3
[3] = AND logic operation input 4
[4] = AND logic operation input 5
[5] = AND logic operation input 6
Note:
F-DO: Failsafe Digital Output
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
No function
Drive group 1 pulses canceled
Drive group 1 SS1 active
Drive group 1 SS2 active
Drive group 1 SOS active
Drive group 1 SLS active
Drive group 1 SSM feedback signal active
Drive group 1 safe state
Drive group 1 SOS selected
Drive group 1 internal event
Drive group 2 pulses canceled
Drive group 2 SS1 active
Drive group 2 SS2 active
Drive group 2 SOS active
Drive group 2 SLS active
Drive group 2 SSM feedback signal active
Drive group 2 safe state
Drive group 2 SOS selected
Drive group 2 internal event
Drive group 3 pulses canceled
Drive group 3 SS1 active
Drive group 3 SS2 active
Drive group 3 SOS active
Drive group 3 SLS active
Drive group 3 SSM feedback signal active
Drive group 3 safe state
Drive group 3 SOS selected
Drive group 3 internal event
Drive group 4 pulses canceled
Drive group 4 SS1 active
Drive group 4 SS2 active
Drive group 4 SOS active
Drive group 4 SLS active
Drive group 4 SSM feedback signal active
Drive group 4 safe state
Drive group 4 SOS selected
Drive group 4 internal event
Calculated: -
Dynamic index: -
Units group: -
Max
777
Parameters
List of parameters
Access level: 3
Func. diagram: 2857
Unit selection: -
Expert list: 1
Factory setting
0
1-1063