Siemens SINAMICS S Series List Manual page 980

Hide thumbs Also See for SINAMICS S Series:
Table of Contents

Advertisement

Parameters
List of parameters
p9346
SI motion SSM velocity limit (Motor Module) / SI Mtn SSM v_limMM
SERVO, VECTOR
Can be changed: C2
Data type: Floating Point
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [mm/min]
Description:
Sets the velocity limit for the SSM feedback signal to detect standstill.
When this limit value is fallen below, the signal "SSM feedback signal active" is set.
Dependency:
Refer to: p9546
Caution:
The function "Safe Acceleration Monitor" (SBR) is switched-out after the selected threshold value is fallen below.
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
A change only becomes effective after a POWER ON.
SBR: Safe Acceleration Monitor
SSM: Safe Speed Monitor (safety-relevant feedback signal from the velocity monitoring)
p9346
SI motion SSM velocity limit (Motor Module) / SI Mtn SSM v_limMM
SERVO (Safety rot),
Can be changed: C2
VECTOR (Safety rot)
Data type: Floating Point
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [RPM]
Description:
Sets the velocity limit for the SSM feedback signal to detect standstill.
When this limit value is fallen below, the signal "SSM feedback signal active" is set.
Dependency:
Refer to: p9546
Caution:
The function "Safe Acceleration Monitor" (SBR) is switched-out after the selected threshold value is fallen below.
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
A change only becomes effective after a POWER ON.
SBR: Safe Acceleration Monitor
SSM: Safe Speed Monitor (safety-relevant feedback signal from the velocity monitoring)
p9348
SI motion SBR actual velocity tolerance (Motor Module) / SI Mtn SBR Tol MM
SERVO, VECTOR
Can be changed: C2
Data type: Floating Point
P-Group: Safety Integrated
Not for motor type: -
Min
0.00 [mm/min]
Description:
Sets the velocity tolerance for the "Safe Acceleration Monitor".
Dependency:
Refer to: p9548
Refer to: C01706
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
A change only becomes effective after a POWER ON.
SBR: Safe Acceleration Monitor
1-980
Calculated: -
Dynamic index: -
Units group: -
Max
1000000.00 [mm/min]
Calculated: -
Dynamic index: -
Units group: -
Max
1000000.00 [RPM]
Calculated: -
Dynamic index: -
Units group: -
Max
120000.00 [mm/min]
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
20.00 [mm/min]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
20.00 [RPM]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
300.00 [mm/min]