SITRANS IQ
Communication
SITRANS CC240 and
SITRANS MX300
Operating Instructions
7MP2200-1CC15-2AA0 (SITRANS CC240)
7MP2200-1AD10-2AA0 (SITRANS MX300)
06/2021
A5E47280695-AB
Getting started
Introduction
Safety notes
Description
Installing/mounting
Connecting
Parameter assignment/
addressing
Service and maintenance
Diagnostics and
troubleshooting
Technical data
Dimension drawings
Ordering data
Product documentation and
support
ESD Directive
Abbreviations
1
2
3
4
5
6
7
8
9
10
11
12
A
B
C

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SITRANS IQ

  • Page 1 Getting started Introduction Safety notes SITRANS IQ Description Communication SITRANS CC240 and Installing/mounting SITRANS MX300 Connecting Operating Instructions Parameter assignment/ addressing Service and maintenance Diagnostics and troubleshooting Technical data Dimension drawings Ordering data Product documentation and support ESD Directive 7MP2200-1CC15-2AA0 (SITRANS CC240)
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents Getting started ............................7 Commission SITRANS CC240 with SITRANS MX300 ............... 7 Connecting HART devices to SITRANS MX300 ............... 8 Calling the SITRANS CC240 web server ................13 Establishing a connection to MindSphere ................14 Establishing a connection to the OPC UA client ..............18 Introduction ............................
  • Page 4 Table of contents Installing SITRANS MX300 on DIN rail ................. 38 Connecting ............................41 Basic safety notes....................... 41 Connecting HART devices to SITRANS MX300 ..............42 Connect SITRANS MX300 to SITRANS CC240............... 47 Pin assignment of the RS-485 data cable extension............. 48 Connecting the supply voltage for SITRANS CC240 and MX300...........
  • Page 5 Table of contents Ordering data ............................77 12.1 Accessories ........................77 Product documentation and support ....................79 Product documentation ..................... 79 Technical support....................... 80 ESD Directive............................81 ESD guideline ........................81 Abbreviations............................83 Index ..............................85 SITRANS CC240 and SITRANS MX300 Operating Instructions, 06/2021, A5E47280695-AB...
  • Page 6 Table of contents SITRANS CC240 and SITRANS MX300 Operating Instructions, 06/2021, A5E47280695-AB...
  • Page 7: Getting Started

    Getting started Commission SITRANS CC240 with SITRANS MX300 Before commissioning the devices Observe the following safety instructions: • General safety notes (Page 23) • Basic safety notes: Installing/mounting Permissible mounting positions and mounting types SITRANS CC240 (Page 33) Mounting instructions (Page 34) •...
  • Page 8: Connecting Hart Devices To Sitrans Mx300

    Getting started 1.2 Connecting HART devices to SITRANS MX300 8. Connect the LAN interface X1P1LAN of the SITRANS CC240 to your PC. Connecting Ethernet to SITRANS CC240 (Page 49) 9. Configuring and addressing SITRANS CC240. Calling the SITRANS CC240 web server (Page 52) Connecting HART devices to SITRANS MX300 Introduction SITRANS MX300 always acts as a secondary master in accordance with the HART standard.
  • Page 9 Getting started 1.2 Connecting HART devices to SITRANS MX300 Connecting SITRANS MX300 with HART Master 1. If a HART Master exists for a channel, connect the SITRANS MX300 parallel to the HART device for this channel. 2. Disable [DISABLED] the corresponding HART resistor at the SITRANS MX300 [HART RESISTOR].
  • Page 10 Getting started 1.2 Connecting HART devices to SITRANS MX300 SITRANS CC240 and SITRANS MX300 Operating Instructions, 06/2021, A5E47280695-AB...
  • Page 11 Getting started 1.2 Connecting HART devices to SITRANS MX300 Connecting SITRANS MX300 without HART Master 1. If no HART Master exists for a channel, connect the SITRANS MX300 for this channel in series to the HART device. 2. Enable [ENABLED] the corresponding HART resistor. (Default: disabled [DISABLED]) 3.
  • Page 12 Getting started 1.2 Connecting HART devices to SITRANS MX300 Example A HART Master is available for Channel 1. • Disable [DISABLED] the DIP switch 1 at the SITRANS MX300 [HART RESISTOR]. • Connect the SITRANS MX300 in parallel to the HART device. SITRANS CC240 and SITRANS MX300 Operating Instructions, 06/2021, A5E47280695-AB...
  • Page 13: Calling The Sitrans Cc240 Web Server

    Getting started 1.3 Calling the SITRANS CC240 web server Calling the SITRANS CC240 web server Procedure 1. Make the network settings for your PC. PC setup (Page 51) 2. Enter the following address in the Google Chrome browser: https:\\192.168.200.1 3. Wait for a few minutes until the system has started up. The "Connection refused"...
  • Page 14: Establishing A Connection To Mindsphere

    Getting started 1.4 Establishing a connection to MindSphere 13.Click the "Reboot" button. 14.Select "Dashboard" in the main menu after logging in again. ⇒ The connected SITRANS MX300 and HART devices are displayed with diagnostics. Figure 1-1 SITRANS CC240 Web Server dashboard Establishing a connection to MindSphere Introduction You can connect SITRANS CC240 to MindSphere.
  • Page 15 Getting started 1.4 Establishing a connection to MindSphere Link to download the templates (https://support.industry.siemens.com/cs/ww/en/ps/28194/dl) • CC240_GenericHART_aspect.csv • CC240_GenericHART_datamapping.csv • CC240_ParameterList.xlsx Generating an onboarding key in MindSphere 1. Call up the SITRANS CC240 web server. Calling the SITRANS CC240 web server (Page 52) 2.
  • Page 16 Getting started 1.4 Establishing a connection to MindSphere Pasting the onboarding key into the SITRANS CC240 web server 1. Select the "Data Logging | Cloud Connectivity" main menu on the SITRANS CC240 web server. ① 2. Click the "Door key" symbol in the table.
  • Page 17 Result In MindSphere, you can now also use the "Agent Diagnostic" to check whether the connection is set up. (Page 56) See also SITRANS CC240 parameter list (https://support.industry.siemens.com/cs/us/en/view/ 109783574) Link to MindSphere (https://pdde.eu1.mindsphere.io/) Getting Connected to MindSphere (https://documentation.mindsphere.io/resources/pdf/ getting-connected-en.pdf) MindSphere documentation area (http://documentation.mindsphere.io)
  • Page 18: Establishing A Connection To The Opc Ua Client

    Getting started 1.5 Establishing a connection to the OPC UA client Establishing a connection to the OPC UA client Before establishing a connection to the OPC UA client • You have installed an OPC UA client, for example: UAExpert installed The OPC UA connection must have the following properties: –...
  • Page 19: Introduction

    Introduction Purpose of this documentation These instructions contain all information required to commission and use the device. Read the instructions carefully prior to installation and commissioning. In order to use the device correctly, first review its principle of operation. The instructions are aimed at persons mechanically installing the device, connecting it electronically, configuring the parameters and commissioning it, as well as service and maintenance engineers.
  • Page 20: Scope Of Delivery

    This product includes third-party software. Siemens AG only provides a warranty for updates/ patches of the third-party software, if these have been distributed as part of a Siemens software update service contract or officially released by Siemens AG. Otherwise, updates/patches are undertaken at your own risk.
  • Page 21: Transportation And Storage

    The content reflects the technical status at the time of publishing. Siemens reserves the right to make technical changes in the course of further development.
  • Page 22 Introduction 2.7 Notes on warranty SITRANS CC240 and SITRANS MX300 Operating Instructions, 06/2021, A5E47280695-AB...
  • Page 23: Safety Notes

    Safety notes Basic safety notes WARNING Life-threatening voltages are present with an open control cabinet When you install the device in a control cabinet, some areas or components in the open control cabinet may be carrying life-threatening voltages. If you touch these areas or components, you may be killed by electric shock. Switch off the power supply to the cabinet before opening it.
  • Page 24 Safety notes 3.1 Basic safety notes NOTICE Use in the scope of application for the UL61010-2-201 When the device is used in the area of Industrial Control Equipment in accordance with UL61010‑2‑201, observe that the device is classified as "Open Type". A UL61010‑2‑201 conform enclosure is therefore a mandatory requirement for approval or operation according to UL61010‑2‑201.
  • Page 25 Safety notes 3.1 Basic safety notes Battery and rechargeable battery WARNING Risk of explosion and release of harmful substances Improper handling of lithium batteries can result in an explosion of the batteries. Explosion of the batteries and the released pollutants can cause severe physical injury. Worn batteries jeopardize the function of the device.
  • Page 26: Notes On Use

    Safety notes 3.3 Prerequisites for safe use Diagnostic data Note SITRANS CC240 supplies diagnostic data to the web server, OPC UA Server, etc. Adaptations to the plant or devices must be checked and implemented using the existing engineering system. Notes on use NOTICE Possible functional restrictions in case of non-validated plant operation The device is tested and certified on the basis of the technical standards.
  • Page 27: Requirements For Special Applications

    Note Operation under special ambient conditions We highly recommend that you contact your Siemens representative or our application department before you operate the device under special ambient conditions as can be encountered in nuclear power plants or when the device is used for research and development purposes.
  • Page 28 Safety notes 3.4 Requirements for special applications SITRANS CC240 and SITRANS MX300 Operating Instructions, 06/2021, A5E47280695-AB...
  • Page 29: Description

    Description Area of application SITRANS CC240 Features • High degree of ruggedness • Compact design • External RS485, Ethernet and USB interfaces • Maintenance-free operation possible • Intel Quark X1020 processor • 1 GB RAM • Battery-buffered real-time clock SITRANS CC240 and SITRANS MX300 Operating Instructions, 06/2021, A5E47280695-AB...
  • Page 30: Sitrans Cc240 Design

    Description 4.2 SITRANS CC240 design SITRANS CC240 design Top view Front view Bottom view ① ⑧ Openings for push-in lugs for wall mounting Securing device ② ⑨ Markings for the installation of antennae RESET button for the CPU ③ ⑩ Connecting the power supply LAN interface X1P1LAN: •...
  • Page 31: Sitrans Mx300 Design

    Description 4.3 SITRANS MX300 design SITRANS MX300 design ① 1 to 8 Channels for the connection of devices with HART ② Left-hand side: Nameplate (Page 32) ③ T-plug for mounting on DIN rail ④ DIP switch Modbus address ⑤ DIP switch terminating resistor ⑥...
  • Page 32: Sitrans Mx300 Nameplate Layout

    Description 4.4 SITRANS MX300 nameplate layout SITRANS MX300 nameplate layout ① Product name ② Place of manufacture ③ Manufacturer's address ④ Serial number ⑤ Article number ⑥ Manufacturer Figure 4-1 Example of the layout of the SITRANS MX300 nameplate SITRANS CC240 and SITRANS MX300 Operating Instructions, 06/2021, A5E47280695-AB...
  • Page 33: Installing/Mounting

    Installing/mounting Permissible mounting positions and mounting types SITRANS CC240 The device can be attached horizontally or vertically on a DIN rail or to a wall. Horizontal mounting position, preferred Vertical mounting position Take into account the permitted temperature range for operation that depends on the mounting position in accordance with the "Technical specifications (Page 71)"...
  • Page 34: Mounting Instructions

    • For installation in a cabinet, observe the SIMATIC setup guidelines (http:// support.automation.siemens.com/WW/view/de/1064706) as well as the relevant DIN/VDE requirements or the applicable country-specific regulations. • When the device is used in the area of Industrial Control Equipment in accordance with UL61010‑2‑201, note that the device is classified as "Open Type".
  • Page 35: Installing Sitrans Cc240 On Din Rail

    Installing/mounting 5.4 Mounting SITRANS CC240 on a wall Installing SITRANS CC240 on DIN rail Before you install the device • You have installed a DIN rail with 35 mm standard profile at the installation site. Procedure Installing the device 1. Place the device and rail clip on the upper edge of the standard profile rail at the posi‐...
  • Page 36 Installing/mounting 5.4 Mounting SITRANS CC240 on a wall Procedure for mounting 1. Guide a push-in lug through the correspond‐ ing opening at the top of the device, as shown 2. Press the push-in lug down. 3. Mark the bore holes, drill the required holes in the wall and fasten the de‐...
  • Page 37: Permissible Mounting Positions And Mounting Types Sitrans Mx300

    Installing/mounting 5.5 Permissible mounting positions and mounting types SITRANS MX300 Permissible mounting positions and mounting types SITRANS MX300 The device can be attached horizontally or vertically on a DIN rail or to a wall. Horizontal mounting position, preferred Vertical mounting position Take into account the permitted temperature range for operation that depends on the mounting position in accordance with the "Technical specifications (Page 71)"...
  • Page 38: Installing Sitrans Mx300 On Din Rail

    Installing/mounting 5.6 Installing SITRANS MX300 on DIN rail Installing SITRANS MX300 on DIN rail Before you install the device • You need a 35 mm DIN rail according to DIN EN 60715. Procedure 1. SITRANS MX300 with existing HART Master: Disable [DISABLED] the corresponding HART resistor at the SITRANS MX300 [HART RESISTOR].
  • Page 39 Installing/mounting 5.6 Installing SITRANS MX300 on DIN rail ② 3. Set a Modbus address [MODBUS ADDRESS SELECTOR] for each SITRANS MX300. Assign each Modbus address only once. Gaps may exist. Example: 2, 5 and 7. In the figure, Modbus address 2 is set. Modbus address Disabled Disabled...
  • Page 40 Installing/mounting 5.6 Installing SITRANS MX300 on DIN rail ③ 6. Enable [ENABLED] the termination resistance [TERMINATION RESISTANCE] of the last bus node of the SITRANS MX300 series. 7. Plug the devices onto the T-plugs. 8. Ground the standard mounting rail. See also Connecting HART devices to SITRANS MX300 (Page 42) SITRANS CC240 and SITRANS MX300...
  • Page 41: Connecting

    Connecting Basic safety notes CAUTION Incorrect loop current Device damage or fire hazard of the 250 Ω input resistance in the SITRANS MX300 due to incorrect loop current. • Maintain the maximum loop current per channel of 35 mA. NOTICE Condensation in the device Damage to device through formation of condensation if the temperature difference between transportation or storage and the mounting location exceeds 20 °C (36 °F).
  • Page 42: Connecting Hart Devices To Sitrans Mx300

    Connecting 6.2 Connecting HART devices to SITRANS MX300 NOTICE Fault caused by I/O devices The connection of I/O devices can cause faults in the device. The result may be personal injury and damage to the machine or plant. Note the following when connecting I/O devices: •...
  • Page 43 Connecting 6.2 Connecting HART devices to SITRANS MX300 Connecting SITRANS MX300 with HART Master 1. If a HART Master exists for a channel, connect the SITRANS MX300 parallel to the HART device for this channel. 2. Disable [DISABLED] the corresponding HART resistor at the SITRANS MX300 [HART RESISTOR].
  • Page 44 Connecting 6.2 Connecting HART devices to SITRANS MX300 SITRANS CC240 and SITRANS MX300 Operating Instructions, 06/2021, A5E47280695-AB...
  • Page 45 Connecting 6.2 Connecting HART devices to SITRANS MX300 Connecting SITRANS MX300 without HART Master 1. If no HART Master exists for a channel, connect the SITRANS MX300 for this channel in series to the HART device. 2. Enable [ENABLED] the corresponding HART resistor. (Default: disabled [DISABLED]) 3.
  • Page 46 Connecting 6.2 Connecting HART devices to SITRANS MX300 Example A HART Master is available for Channel 1. • Disable [DISABLED] the DIP switch 1 at the SITRANS MX300 [HART RESISTOR]. • Connect the SITRANS MX300 in parallel to the HART device. SITRANS CC240 and SITRANS MX300 Operating Instructions, 06/2021, A5E47280695-AB...
  • Page 47: Connect Sitrans Mx300 To Sitrans Cc240

    Connecting 6.3 Connect SITRANS MX300 to SITRANS CC240. Connect SITRANS MX300 to SITRANS CC240. Before connecting the devices You have grounded the standard mounting rails. Procedure 1. Connect the SITRANS MX300 using the supplied RS485 data cable to SITRANS CC240 port "X30COM".
  • Page 48: Pin Assignment Of The Rs-485 Data Cable Extension

    Connecting 6.5 Connecting the supply voltage for SITRANS CC240 and MX300 Pin assignment of the RS-485 data cable extension Note Functional faults may occur with cable lengths greater than 2 m. Supply cable: 2 x cable cross-section of 0.75 mm RS-485 cable: 2 cores and a shield Impedance: 120 ohms...
  • Page 49: Connecting Ethernet To Sitrans Cc240

    Connecting 6.7 Securing the cables Before switching on the supply voltage • The flammability class of the wires conforms to safe operation according to VW-1. • You are using the supplied terminal. • A two-core cable with a cable cross-section of 0.75 mm to 2.5 mm •...
  • Page 50 Connecting 6.7 Securing the cables SITRANS CC240 and SITRANS MX300 Operating Instructions, 06/2021, A5E47280695-AB...
  • Page 51: Parameter Assignment/Addressing

    Parameter assignment/addressing PC setup Before setting up your PC The devices are connected and supplied. Refer to section: Connecting (Page 41). Procedure 1. Navigate to the settings of the used LAN network adapter. In Windows 10: Windows "Settings > Network and Internet > Change adapter settings" 2.
  • Page 52: Calling The Sitrans Cc240 Web Server

    Parameter assignment/addressing 7.2 Calling the SITRANS CC240 web server 5. Change the IP address. The address must not match the address of the device. The default IP address of the device is 192.168.200.1. Your computer must be in the same network to communicate with the device.
  • Page 53: Establishing A Connection To Mindsphere

    Parameter assignment/addressing 7.3 Establishing a connection to MindSphere 13.Click the "Reboot" button. 14.Select "Dashboard" in the main menu after logging in again. ⇒ The connected SITRANS MX300 and HART devices are displayed with diagnostics. Figure 7-2 SITRANS CC240 Web Server dashboard Establishing a connection to MindSphere Introduction You can connect SITRANS CC240 to MindSphere.
  • Page 54 Parameter assignment/addressing 7.3 Establishing a connection to MindSphere Link to download the templates (https://support.industry.siemens.com/cs/ww/en/view/ 109792858) • CC240_GenericHART_aspect.csv • CC240_GenericHART_datamapping.csv • CC240_ParameterList.xlsx Generating an onboarding key in MindSphere 1. Call up the SITRANS CC240 web server. Calling the SITRANS CC240 web server (Page 52) 2.
  • Page 55 Parameter assignment/addressing 7.3 Establishing a connection to MindSphere Pasting the onboarding key into the SITRANS CC240 web server 1. Select the "Data Logging | Cloud Connectivity" main menu on the SITRANS CC240 web server. ① 2. Click the "Door key" symbol in the table.
  • Page 56: Checking The Connection To Mindsphere

    Parameter assignment/addressing 7.3 Establishing a connection to MindSphere ⑤ 6. Activate the connection via the slider to the right. ⑥ 7. Click the "Save Changes" button. Result In MindSphere, you can now also use the "Agent Diagnostic" to check whether the connection is set up.
  • Page 57: Show Data In Mindsphere

    Parameter assignment/addressing 7.3 Establishing a connection to MindSphere 4. Select your created "Asset Agent". For example, CC240Agent 5. Click on "View Logs". For the first call, it can take up to 10 minutes until the data is displayed in MindSphere. The data is uploaded about every 4 minutes from the SITRANS CC240 web server to MindSphere.
  • Page 58: Establishing A Connection To The Opc Ua Client

    Parameter assignment/addressing 7.4 Establishing a connection to the OPC UA client 4. Click on the "Edit boarding configuration" button at the top right. 5. Generate an onboarding key. Note: After each change in MindSphere, generate the onboarding key again and update the onboarding key in the SITRANS CC240 web server.
  • Page 59: Showing Process Values In The Sitrans Cc240 Web Server

    Parameter assignment/addressing 7.5 Showing process values in the SITRANS CC240 web server 9. Call up the SITRANS CC240 web server. Calling the SITRANS CC240 web server (Page 52) 10.Select "OPC UA Server > Certificate Management" from the main menu. 11.Refresh the page. 12.Verify and confirm the OPC UA client certificate on the SITRANS CC240 web server.
  • Page 60 Parameter assignment/addressing 7.5 Showing process values in the SITRANS CC240 web server 3. Click "Find MX300s". You can see the connected SITRANS MX300 (e.g. Shield 2) and HART devices (e.g. Channel 3). 4. Use the slider to disable SITRANS MX300 (e.g. MX300 address 5) or HART devices (e.g. Channel 3).
  • Page 61: User Management In The Sitrans Cc240 Web Server

    Parameter assignment/addressing 7.6 User management in the SITRANS CC240 web server User management in the SITRANS CC240 web server Table 7-1 User role: Administrator Network settings Read/write Access to devices / chan‐ Read/write nels Data Logging | Cloud Read/write Connectivity System information Read/write Task Manager visible...
  • Page 62 Parameter assignment/addressing 7.6 User management in the SITRANS CC240 web server OPC UA client certificate Read/write management Data viewer Read/write Table 7-3 User role: Analyst Network settings Read Access to devices / chan‐ Read nels Data Logging | Cloud Read Connectivity System information Read...
  • Page 63: Service And Maintenance

    Service and maintenance Basic safety notes Note The device is maintenance-free. 8.1.1 Maintenance To retain a high level of system availability, or devices with a back-up battery, we recommend the preventative replacement of the back-up battery at replacement intervals of 5 years. 8.1.2 Repair information Carrying out repairs...
  • Page 64: Disposal

    Further information about devices containing batteries can be found at: Information on battery/product return (WEEE) (https:// support.industry.siemens.com/cs/document/109479891/) Note Special disposal required The device includes components that require special disposal. • Dispose of the device properly and environmentally through a local waste disposal contractor.
  • Page 65: Maintenance And Repair Work

    • Repair must be carried out by Siemens authorized personnel only. WARNING Impermissible repair and maintenance of the device • Repair and maintenance must be carried out by Siemens authorized personnel only. CAUTION Hazardous voltage at open device Risk of electric shock when the enclosure is opened or enclosure parts are removed.
  • Page 66 Service and maintenance 8.3 Maintenance and repair work NOTICE Disposal of batteries and rechargeable batteries Batteries and rechargeable batteries do not belong in domestic garbage. The user is legally obliged to return used batteries and rechargeable batteries. Used batteries and rechargeable batteries pollute the environment as special waste. You as a user are liable to prosecution if you do not properly dispose of batteries and rechargeable batteries.
  • Page 67: Return Procedure

    Enclose the delivery note, returned goods delivery note in a clear plastic pouch and attach it firmly to the outside of the packaging. Required forms • Delivery note • Return document (http://www.siemens.com/processinstrumentation/returngoodsnote) with the following information: – Product (item description) – Number of returned devices/replacement parts –...
  • Page 68 Service and maintenance 8.4 Return procedure SITRANS CC240 and SITRANS MX300 Operating Instructions, 06/2021, A5E47280695-AB...
  • Page 69: Diagnostics And Troubleshooting

    Diagnostics and troubleshooting Meaning of the LED states on SITRANS MX300 LED state Error Causes and remedies LEDs 1 to 8 flashing green 2x per second. Modbus address of the SITRANS MX300 Two devices have the same Modbus ad‐ is invalid. dress.
  • Page 70: Troubleshooting

    Diagnostics and troubleshooting 9.2 Troubleshooting Troubleshooting Symptom Cause of error Remedy You have connected new devices, but The SITRANS CC240 web server automat‐ To start the search manually, click the they do not appear on the SI‐ ically looks for new devices every 24 hrs. "Scan"...
  • Page 71: Technical Data

    Technical data 10.1 General technical specifications General technical specifications SITRANS CC240 SITRANS MX300 Article number See order documents Weight without mounting brack‐ Approx. 230 g Approx. 150 g Power supply 9 to 35 V DC, no electrical isola‐ 9 to 35 V DC, with electrical iso‐ tion lation (supply to HART channels and to...
  • Page 72: Ambient Conditions

    Technical data 10.2 Ambient conditions If there are voltage peaks on the power supply lines, use a protective device in the form of a varistor (MOV) UMOV = Urated x 1.2 (BLITZDUCTOR BVT AVD 24 (918 422) or compatible). Interfaces SITRANS CC240 SITRANS MX300 LAN interface RJ45...
  • Page 73: Direct Current Supply (Dc)

    Technical data 10.3 Direct current supply (DC) SITRANS CC240 SITRANS MX300 5 to 95% at 25/55 °C, no conden‐ 5 to 80% at 25/55 °C, no conden‐ • Storage/transport sation sation Atmospheric pressure 1080 … 795 hPa, corresponds to 1080 to 795 hPa •...
  • Page 74 Technical data 10.3 Direct current supply (DC) SITRANS CC240 and SITRANS MX300 Operating Instructions, 06/2021, A5E47280695-AB...
  • Page 75: Dimension Drawings

    Dimension drawings 11.1 SITRANS CC240 dimension drawings Figure 11-1 Dimension drawings SITRANS CC240, dimensions in mm (inch) SITRANS CC240 and SITRANS MX300 Operating Instructions, 06/2021, A5E47280695-AB...
  • Page 76: Sitrans Mx300 Dimension Drawings

    Dimension drawings 11.2 SITRANS MX300 dimension drawings 11.2 SITRANS MX300 dimension drawings Figure 11-2 Dimension drawings SITRANS MX300, dimensions in mm (inch) SITRANS CC240 and SITRANS MX300 Operating Instructions, 06/2021, A5E47280695-AB...
  • Page 77: Ordering Data

    Ordering data 12.1 Accessories You can order accessories online: Industry Mall (https://mall.industry.siemens.com) The following accessories are not included in the scope of delivery: • Push-in lugs • Storage media SITRANS CC240 and SITRANS MX300 Operating Instructions, 06/2021, A5E47280695-AB...
  • Page 78 Ordering data 12.1 Accessories SITRANS CC240 and SITRANS MX300 Operating Instructions, 06/2021, A5E47280695-AB...
  • Page 79: Product Documentation And Support

    – "Download as html5, only PC": Open or save the manual in the HTML5 view on your PC You can also find manuals with the Mobile app at Industry Online Support (https:// support.industry.siemens.com/cs/ww/de/sc/2067). Download the app to your mobile device and scan the device QR code. Product documentation by serial number Using the PIA Life Cycle Portal, you can access the serial number-specific product information including technical specifications, spare parts, calibration data, or factory certificates.
  • Page 80: Technical Support

    Additional information on our technical support can be found at Technical Support (http:// www.siemens.com/automation/csi/service). Service & support on the Internet In addition to our technical support, Siemens offers comprehensive online services at Service & Support (http://www.siemens.com/automation/serviceandsupport). Contact If you have further questions about the device, contact your local Siemens representative at Personal Contact (http://www.automation.siemens.com/partner).
  • Page 81: Esd Directive

    ESD Directive ESD guideline What does ESD mean? An electronic module is equipped with highly integrated components. Due to their design, electronic components are highly sensitive to overvoltage and thus to the discharge of static electricity. Such electronic components or modules are labeled as electrostatic sensitive devices. The following abbreviations are commonly used for electrostatic sensitive devices: •...
  • Page 82 ESD Directive B.1 ESD guideline ① Synthetic materials ② Wool ③ Antistatic materials such as wood or concrete NOTICE Grounding measures There is no equipotential bonding without grounding. An electrostatic charge is not discharged and may damage the ESD. Protect yourself against discharge of static electricity. When working with electrostatic sensitive devices, make sure that the person and the workplace are properly grounded.
  • Page 83: Abbreviations

    Abbreviations ACPI Advanced Configuration and Pow‐ er Interface BIOS Basic Input Output System Communauté Européenne Central Processing Unit Canadian Standards Association Canadian organization for tests and certifications according to national or binational standards Clear To Send Clear to send Direct Current DC current Data Carrier Detect Data carrier signal detection...
  • Page 84 Abbreviations UEFI Unified Extensible Firmware Inter‐ face Underwriters Laboratories Inc. US organization for testing and certification ac‐ cording to national or binational standards. Universal Serial Bus SITRANS CC240 and SITRANS MX300 Operating Instructions, 06/2021, A5E47280695-AB...
  • Page 85: Index

    Index Accessories, 77 HART RESISTOR, 38 Hazardous area Laws and directives, 26 Hotline, (Refer to Support request) Backup battery Installing, 66 Installation on a DIN rail, 33, 37 Installing Backup battery, 66 Catalog Interfaces, 72 catalog sheets, 79 Certificates, 26, 79 Clearance, 33, 37 Components sensitive to electrostatic charge, 81 Connecting...
  • Page 86 Index PROFINET, 73 Protective measure Static electricity, 82 Radiation, 25 High frequency radiation, 25 Repairs, 63 Return procedure, 67 Scope of delivery, 19 Service, 80 Service and support Internet, 80 Standard mounting rail, 31, 38, 39 Static electricity Protective measures, 82 Supply voltage, 71 Support, 80 Support request, 80...