Parameters
List of parameters
Re bit 00 = 1:
The encoder is parked. Contrary to r0481.14, parking is also displayed here if the suppression of the parking bit is
active in r0481.14 (p3870.1 = 1).
Re bit 01 = 1:
The long-stator functions requested closed-loop velocity control with encoder. In r1407.2, it is indicated as to
whether an encoder is actually used for the closed-loop control.
p3876
BI: Unpark long stator signal source 1 encoder / S_src 1 enc unpark
SERVO
Can be changed: T
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source 1 to unpark the encoder.
Dependency:
Refer to: p3870, p3871, p3872, p3873, p3874, r3875, p3878, p3879
Note:
BI: p3876 = 1 signal --> encoder is unparked
BI: p3876 = 0 signal --> encoder is parked
p3878
CO: Long stator commutation angle 1 / Com_angle 1
SERVO
Can be changed: U, T
Data type: Floating Point
P-Group: -
Not for motor type: -
Min
-180 [°]
Description:
Enters the commutation angle 1 for long stator motors.
Dependency:
Refer to: p3870, p3871, p3872, p3873, p3874, r3875, p3876, p3879
p3879
CO: Long stator commutation angle 2 / Com_angle 2
SERVO
Can be changed: U, T
Data type: Floating Point
P-Group: -
Not for motor type: -
Min
-180 [°]
Description:
Enters the commutation angle 2 for long stator motors.
Dependency:
Refer to: p3870, p3871, p3872, p3873, p3874, r3875, p3876, p3878
p3900
Completion of quick commissioning / Compl quick_comm
A_INF, B_INF,
Can be changed: C2(1)
S_INF
Data type: Integer16
P-Group: -
Not for motor type: -
Min
0
Description:
Exits the quick commissioning (p0010 = 1) with automatic calculation of all of the parameters that depend on the
entries made during the quick commissioning.
p3900 = 1 initially includes a parameter reset (factory setting, the same as p0970 = 1) for all parameters of the drive
object; however, without overwriting the entries made during the quick commissioning. The interconnections of
PROFIBUS PZD telegram selection (p0922) and the interconnections via p0700 are re-established and all of the
dependent filter and closed-loop control parameters are calculated (corresponding to p0340 = 1).
1-764
Calculated: -
Dynamic index: -
Units group: -
Max
-
Calculated: -
Dynamic index: -
Units group: -
Max
180 [°]
Calculated: -
Dynamic index: -
Units group: -
Max
180 [°]
Calculated: -
Dynamic index: -
Units group: -
Max
3
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0 [°]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0 [°]
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0