+24 V
X521.5
X521.3
DI/DO 2
<1>
X521.4
DI/DO 3
<1>
X522.M1
M
<1> The connection shown as a dashed line applies when set as digital output (p4028.x = 1).
1
2
DO: TM41
Terminal Module 41 (TM41) - Digital inputs/outputs, bidirectional (DI/DO 2 ... DI/DO 3)
+
[9562.3]
p4028.10 (0)
24 V
DI
DI
0
1
DO
DO
5 V
p4028.11 (0)
DI
24 V
DI
0
1
DO
DO
5 V
3
4
Simulation
p4095.10 (0)
p4096.10
1
r4021.10
0
DI/DO 2 (X521.3)
r4047.10
p4048.10 (0)
0
-1
1
Simulation
p4095.11 (0)
p4096.11
r4021.11
1
0
DI/DO 3 (X521.4)
r4047.11
p4048.11 (0)
0
-1
1
5
6
fp_9662_51_eng.vsd
01.08.07 V02.05.00
p4099[0] (4000.00 µs)
TM41 DI status inv
TM41 DI status
r4023
r4022
1
r4023.10
DI/DO 2 (X521.3)
r4022.10
TM41 S_src DI/DO 2
p4040(0)
1
r4023.11
DI/DO 3 (X521.4)
r4022.11
TM41 S_src DI/DO 3
p4041(0)
7
8
Function diagram