Flux build-up ctrl
p1401.2
Saturation characteristic
Suppl flux setpoint
0.0...100.0 [%]
p1572[D] (0.0)
Flux setpoint total
[6725.8]
r1598
+
Flux actual value T_smth
0...1000 [ms]
p1585[D] (0)
Flux actual value
[6732.1]
r0084[0]
1
2
DO: VECTOR
Vector control - Field weakening controller, flux controller (FEM, p0300 = 5)
[6491]
Flux differentiation
p1401.1
0
0
Id_set steady-state
1
r1623
+
+
P0360
Mot Lh/Lhd sat
p0362 ... p0369
Flux controller Kp
Flux controller Tn
0.0...999999.0
0...10000 [ms]
p1590[D] (10.0)
p1592[D] (30)
+
P flux controller Kp
p1600[D] (10.0)
Flux tracking thresh
0.0...100.0 [%]
p1705[D] (100.0)
+
Flux tracking
r0084[1]
3
4
I_component
r1593[1]
EMF scal Isq_ctrl
0.0...200.0 [%]
p1704[D] (100.0)
5
6
fp_6726_01_eng.vsd
04.12.06 V02.05.00
p0115[2] (Motor Modules)
Refer to [1020.7]
I_mod_ctrl pre-ctrl
r1618
[6727.2]
I_mod flux setpoint
r1633
[6727.1]
Field flux_ctrl output
r1593[0]
[6727.2]
Flux controller P output
r1602
[6727.2]
[6714.1]
FEM: Separately-excited synchronous motor