Parameters
List of parameters
Dependency:
Refer to: r9744, r9747, r9748, r9749, p9752, r9753, r9754, r9755, p9759
p9759
SI, acknowledge messages, drive object / SI msg ackn DO
SERVO, VECTOR
Can be changed: U, T
Data type: Unsigned8
P-Group: Messages
Not for motor type: -
Min
0
Description:
Acknowledges all safety messages present for a drive object.
Dependency:
Refer to: r9744, r9747, r9748, r9749, p9752, r9753, r9754, r9755, r9756
Note:
Parameter should be set from 0 to 1 to acknowledge.
After acknowledgement, the parameter is automatically reset to 0.
p9761
SI password input / SI password inp
SERVO, VECTOR
Can be changed: C1, T
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
0000 hex
Description:
Enters the Safety Integrated password.
Dependency:
Refer to: F01659
Note:
It is not permissible to change Safety Integrated parameter settings until the Safety Integrated password has been
entered.
p9762
SI password new / SI password new
SERVO, VECTOR
Can be changed: C2
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
0000 hex
Description:
Enters a new Safety Integrated password.
Dependency:
A change made to the Safety Integrated password must be acknowledged in the following parameter:
Refer to: p9763
p9763
SI password acknowledgement / SI ackn password
SERVO, VECTOR
Can be changed: C2
Data type: Unsigned32
P-Group: Safety Integrated
Not for motor type: -
Min
0000 hex
Description:
Acknowledges the new Safety Integrated password.
Dependency:
Refer to: p9762
Note:
The new password entered into p9762 must be re-entered in order to acknowledge.
p9762 = p9763 = 0 is automatically set after the new Safety Integrated password has been successfully acknowl-
edged.
1-1032
Calculated: -
Dynamic index: -
Units group: -
Max
1
Calculated: -
Dynamic index: -
Units group: -
Max
FFFF FFFF hex
Calculated: -
Dynamic index: -
Units group: -
Max
FFFF FFFF hex
Calculated: -
Dynamic index: -
Units group: -
Max
FFFF FFFF hex
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 2800
Unit selection: -
Expert list: 1
Factory setting
0000 hex
Access level: 3
Func. diagram: 2800
Unit selection: -
Expert list: 1
Factory setting
0000 hex
Access level: 3
Func. diagram: 2800
Unit selection: -
Expert list: 1
Factory setting
0000 hex