The block has the following permissions for the OS1Perm parameter:
Bit
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26-31
SITRANS Library for PCS 7
Function Manual, 05/2019, A5E35351976-11
1 = Operator can change the value for the low gradient limit for positive and negative
gradients (GradLLim)
Not used
1 = Operator can activate / deactivate messages with PV_AH_MsgEn
1 = Operator can activate / deactivate messages with PV_WH_MsgEn
1 = Operator can activate / deactivate messages with PV_WL_MsgEn
1 = Operator can activate / deactivate messages with PV_AL_MsgEn
1 = Operator can activate bypass functionality
1 = Operator can deactivate bypass functionality
Not used
Function
1 = Operator can change the limit (Tot) for the high alarm
1 = Operator can change the limit (Tot) for the high warning
1 = Operator can change the limit (Tot) for the hysteresis
1 = Operator can change the limit (Tot) for the low alarm
1 = Operator can change the limit (Tot) for the low warning
1 = Operator can activate / deactivate messages with Tot_AH_MsgEn
1 = Operator can activate / deactivate messages with Tot_WH_MsgEn
1 = Operator can activate / deactivate messages with Tot_WL_MsgEn
1 = Operator can activate / deactivate messages with Tot_AL_MsgEn
1 = Operator may input the 'positive and negative count' totalizer command
1 = Operator may input the 'only positive count' totalizer command
1 = Operator may input the 'only negative count' totalizer command
1 = Operator may input the 'Hold' totalizer command
1 = Operator can reset the totalizer
1 = Operator can preset the totalizer
1 = Operator can read the configuration data from the device
1 = Operator can write the configuration data to the device
1 = Operator can read the min/max pointer values from the module
1 = Operator can reset the maximum min/max pointer value of the pressure
1 = Operator can reset the minimum min/max pointer value of the pressure
1 = Operator can reset the maximum min/max pointer value of the sensor temper‐
ature
1 = Operator can reset the minimum min/max pointer value of the sensor temper‐
ature
1 = Operator can reset the maximum min/max pointer value of the electronics tem‐
perature
1 = Operator can reset the minimum min/max pointer value of the electronics tem‐
perature
1 = Operator can read the sensor and electronics temperature from the module
1 = Operator can change the preset value of the totalizer
Not used
SITRANS P PA
11.1 SitrP_PA
429