Configurable reactions using the Feature/Feature2 parameter
An overview of all the reactions that are provided by the Feature parameter is available in
section "Configurable response using the Feature I/O" in the APL Online Help. The following
reactions are available for this block at the relevant bits:
Bit
0
1
2
3
4
5
6
8
9
10
11
15
16
17
21
22
24
25
26
27
28
29
30
31
In pushbutton mode (bit 4 = 0) the automatic commands in automatic mode are latching, in
other words OpenAut and CloseAut can be reset to zero after changing the control. In manual
and local modes, however, the automatic commands are not saved and in the absence of
automatic commands the automatic control is tracked.
In switching mode (bit 4 = 1), control is selected with the OpenAut static signals. If input
OpenAut is not set the valve is closed. Control via CloseAut is not needed. If the "Activate
command reset for control" function (bit 3 = 1) is also activated, the OpenAut input is reset to
the neutral position after evaluation in the block.
Note
Switching mode can only be used for configuration with the auxiliary valve.
SITRANS Library for PCS 7
Function Manual, 05/2019, A5E35351976-11
Function
Setting the startup characteristics (Page 50)
Reaction to the out of service mode (Page 54)
Resetting the commands for changing the mode (Page 55)
Enabling resetting of commands for the control settings (Page 55)
Set switch or button mode (Page 56)
Control via auxiliary valve (Page 51)
Disabling opening and closing (Page 51)
Separate delay times for each alarm (Page 52)
Resetting interlock via automatic input signals in automatic mode
Exiting local mode (Page 58)
Activating the run time of feedback signals (Page 52)
Neutral position manipulated variable takes effect with "out of service" operating mode
Neutral position manipulated variable takes effect at startup
Enabling bumpless switchover to automatic mode for valves, motors, and dosers (Page 52)
Enabling bumpless changeover to automatic mode only for operator
Update acknowledgment and error status of the message call (Page 60)
Enabling local operating permission (Page 60)
Suppress all messages if MsgLock = 1
Reaction of the switching points in "Out of service" mode
Interlock display with LocalSetting 2 or 4
Disabling operating points (Page 61)
Signaling limit violation (Page 62)
Resetting depending on the operating mode (Page 62)
Activating reset of protection / errors in manual mode (Page 63)
SIPART PS2 PA
8.1 SipPS2PA
275