12. Select T3+ Configuration Utility from the main menu.
13. When prompted, enter the password for the Sun StorEdge T3+ array. Press Return
if no password has been set.
14. Select the Configure T3+ option.
15. Select the Sun StorEdge T3+ host name that you added.
16. Select the Default or Custom option to configure the new Sun StorEdge T3+ array.
17. Type:
msp0# /opt/SUNWstade/bin/config_solution -m model-number
18. Launch the Storage Automated Diagnostic Environment and discover the new Sun
StorEdge T3+ array.
Refer to the Storage Automated Diagnostic Environment User's Guide for detailed
instructions on discovery.
To Upgrade the Sun StorEdge T3+ Array
Firmware
The correct patch number for the firmware is patch ID 112276-nn. This file can be
found in the /export/patches directory on the Storage Service Processor.
1. Log in to the Storage Service Processor.
2. Use the instructions in the Sun StorEdge T3 and T3+ Array Installation, Operation,
and Service Manual to upgrade the firmware.
The procedures in that manual instruct you in the following:
Upgrading the Sun StorEdge T3+ array controller firmware
Upgrading the interconnect card firmware
Upgrading the disk drive firmware
3. Update the Sun StorEdge T3+ array snapshot files on the Storage Service
Processor by running the following command:
# savet3config -n all
Chapter 14 Servicing Sun StorEdge T3+ Arrays
14-7