15. Cut the small wire tie on the back of the Storage Service Processor and remove the
smart card from the unit.

To Replace the Storage Service Processor

1. Establish a connection to the Storage Service Processor.
a. From the onsite system, establish a connection to the Storage Service Processor.
The command used to make the connection vary depending on the onsite system.
For example, from a Solaris server, you would type:
# tip -9600 /dev/ttyb
Connected
When the connection is made, press Return.
b. From a remote system, establish a connection to the site through the Sun
StorEdge Remote Response modem.
i. Connect one end of the service cable to the service port of the service panel
ii. Connect the other end of the service cable to the serial console port of the
iii. Log into the storage processor that is attached to the modem and make a
# tip -9600 /dev/ttyb
Connected
2. Log in as root:
Console login: root
Password: password
3. Change all references of the host name to the name returned in Step 3 of the
Section t, "To Remove the Storage Service Processor" on page 12-13 in the
following files:
12-10
Sun StorEdge 3900 and 6900 Series 1.1 Reference and Service Manual • July 2002
on the Sun StorEdge 3900 or 6900 series storage system that is connected to
the modem.
service panel on the Sun StorEdge 3900 or 6900 series storage system that is
to be remotely configured.
tip(1) connection to /dev/ttyb.
When the connection is made, press Return.